Slotted Tag Fuses

Slotted tag fuses are a type of circuit protection device distinguished by the slotted metal tags that extend off the ends of the cylindrical fuse body. They can either be offset tags or centered in the fuse, according to whether they jut out from the top, bottom or middle of the fuse.

How do slotted tag fuses work?

Slotted tag fuses connect to the circuit by sliding onto a connector or fuse holder using their slotted tag. The metal tag conducts electricity through the fuse. When a fault is detected, such as overcurrent or a short circuit, the metal strip inside of the fuse melts, breaking the circuit and preventing any further damage. When a fuse has blown, it must be replaced in order for the circuit to function again.

Types of slotted tag fuses

Slotted tag fuses can vary in a number of different ways, including their current and voltage rating, the dimension of both the fuse body and the metal tags, and the fuse speed.


...
Read more Read less

Filters

Viewing 101 - 101 of 101 products
Results per page
Description Price Fuse Standard Fuse Size Current Rating Voltage Rating Fuse Speed High Rupture Capacity Body Diameter Overall Length Tag Width Body Height Body Width Body Length Fixing Centres Application Category
RS Stock No. 396-370
Mfr. Part No.3NE3222
BrandSiemens
€136.15
Each (In a Pack of 3)
units
IEC 60269-4-1 C00 125A 1kV - Yes - 135mm 12.5mm 63.5mm 52mm 73mm 110mm aR
Related Products
Eaton Bussmann Series bolted tag fuse is essentially ...
Description:
Eaton Bussmann Series bolted tag fuse is essentially a fuse that is fitted with brackets, these brackets allow the fuse to be bolted onto a fuse holder Predominantly, this type of fuse is used within installations as a "weak link". ...
Cooper Bussman's slotted tag fuse, distinguished by the ...
Description:
Cooper Bussman's slotted tag fuse, distinguished by the slotted metal tags that extend off the ends of the fuse This tag can either enable the fuse to have an offset tag or be centred to the fuse. Predominantly, this type ...
As the fuse allows for the starting surge ...
Description:
As the fuse allows for the starting surge of a motor its full load current must not exceed the lesser of the dual current rating e.g. 20 M25 must not have a continuous load of greater than 20A. Breaking capacity ...
These fuses are designed for : “General purpose ...
Description:
These fuses are designed for : “General purpose use” protection (gG type) or motor protection (gM type) This fuse range insures an excellent current limitation for all overloads on a large range of applications. Their size cannot allow exchange by ...