RTD Calibrators

Filters

Viewing 1 - 8 of 8 products
Results per page
Description Price Temperature Coefficient Best Accuracy Resistance Measurement Resolution Battery Type Calibrated Connector Type Dimensions Weight Absolute Maximum Resistance Measurement Absolute Minimum Resistance Measurement Height Length Maximum Operating Temperature Maximum Temperature Measurement
RS Stock No. 911-9831
Mfr. Part No.TC6622
€802.88
Each
units
±10ppm/°C ±0.012 % 1mΩ AA RSCAL - 157 x 85 x 45mm 306g 3600Ω 45mm 157mm - -
RS Stock No. 911-9835
Mfr. Part No.TC6622
€899.00
Each
units
±10ppm/°C ±0.012 % 1mΩ AA UKAS - 157 x 85 x 45mm 306g 3600Ω 45mm 157mm - -
RS Stock No. 508-3707
Mfr. Part No.TC6622
€719.00
Each
units
±10ppm/°C ±0.012 % 1mΩ AA - - 157 x 85 x 45mm 306g 3.6kΩ 45mm 157mm - -
RS Stock No. 158-8107
Mfr. Part No.1049
€364.33
Each
units
±30ppm/°C ±0.3 °C - - - 4 mm Banana Plug 112 x 61 x 55mm 170g - - 55mm 112mm +60°C +800 °C
RS Stock No. 158-8450
Mfr. Part No.1049
€432.33
Each
units
±30ppm/°C ±0.3 °C - - RSCAL 4 mm Banana Plug 112 x 61 x 55mm 170g - - 55mm 112mm +60°C +800 °C
RS Stock No. 158-8466
Mfr. Part No.1049
€459.33
Each
units
±30ppm/°C ±0.3 °C - - UKAS 4 mm Banana Plug 112 x 61 x 55mm 170g - - 55mm 112mm +60°C +800 °C
RS Stock No. 758-8932
Mfr. Part No.P01654623
€741.00
Each
units
- 0.2 °C, 0.3 °C, 0.33 °C, 0.6 °C, 0.7 °C, 0.8 °C, 1 Ω - AAA - - 97 x 45 x 205mm 472g 3.2kΩ 205mm 97mm - +630 °C, +800 °C
RS Stock No. 423-1646
Mfr. Part No.7000
€957.13
Each
units
- ±0.05 °C 10mΩ Rechargeable NiMH - - 165 x 90 x 45mm 420g 2.6kΩ 0.01Ω 45mm 165mm +50°C -
Related Products
These compact, robust, easy-to-handle calibrators have large LCD ...
Description:
These compact, robust, easy-to-handle calibrators have large LCD screens and are suitable for use in highly diverse on-site conditions. They can calibrate an instrument in its operating environment and without removing it from the process. The principal functions are simulation ...
Additional insert sleeve for use with the 9102S ...
Description:
Additional insert sleeve for use with the 9102S drywell calibrator. ,Use the insert sleeve to correctly fit the sheath of the temperature sensor or device under test.
A drywell heat source offering a combination of ...
Description:
A drywell heat source offering a combination of extreme portability and good performance to meet the requirements associated with high speed, high volume industrial calibrations in a shop floor environment. Use the instruments independently or together to make fast zero ...
A drywell offering a combination of extreme portability ...
Description:
A drywell offering a combination of extreme portability and good performance to meet the requirements associated with high speed, high volume industrial calibrations in a shop floor environment. Use the instruments independently or together to make fast zero and span ...