Phoenix Contact MCR-S10-50-UI-SW-DCI-NC Series Current Sensor, 0 55A, 0 20mA output current

Technical data sheets
Legislation and Compliance
Non Compliant
COO (Country of Origin): DE
Product Details

Phoenix Contact Current Transducer, MCR-S

The Phoenix Contact MCR-S series of Current Transducer brings you reliable signal conversion, allowing you to push the boundaries of your automation, measurement or control systems. Compact in nature and being able to operate in different temperatures, the MCR-S series offers you the stability needed in your working environment. The device is fully programmable and configurable, perfect for measuring direct, alternating or distorted currents.

Features and Benefits

• Built-in 3 number of inputs, with a current range of 0 A to 11 A (AC/DC)

• Power supply voltage range between 20 V DC to 30 V DC, with a Max. current consumption of less than 40 mA (without load)

• The device can be set up via DIP switches or MCR/PI-CONF-WIN configuration software

• True r.m.s value measurement

• Screw connection, M3 screw thread, 8 mm stripping length

• Different coloured status LED colours, available in green, yellow etc.

• IP20 degree of protection, noise immunity to EN 61000-6-2

• Overvoltage electrical category 3

• CE-compliant

Typical Applications

• Control systems

Specifications
Attribute Value
Nominal Current 0 55A
Output Current Range 0 20mA
Supply Voltage 20 30 V dc
Mounting Type Chassis Mount
Frequency Bandwidth 15 400 Hz
Accuracy <0.5 %
Series MCR-S10-50-UI-SW-DCI-NC
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Depth 114.5mm
Height 99mm
Width 22.5mm
3 In stock for delivery within 2 working days
Unit of sale: Each
280.33
(exc. VAT)
344.81
(inc. VAT)
units
Per unit
1 - 4
€280.33
5 - 9
€272.55
10 +
€265.19
Related Products
Opening-type current sensors for electronic measurement of alternating ...
Description:
Opening-type current sensors for electronic measurement of alternating currentGalvanic insulation between primary and secondary circuits.8 mm maximum conductor diameter for TT 50-SD model and 16 mm for TT100-SD model.1 metre length pre-stripped cable.Applications: measurement of active power and calculation of ...
Open Loop Hall Effect current transducers with integral ...
Description:
Open Loop Hall Effect current transducers with integral primary connections for the accurate measurement of current Open Loop (low power consumption)AC,DC, and mixed signal measurement Extended measuring range (3xlpn)Small sizeHX 03-20 (23.5x15.8x19mm)HX 25-50 (20x19x15.4mm)Multi turn Primary Unipolar power supply ...
Flexible alternative to the current shunt or transformers ...
Description:
Flexible alternative to the current shunt or transformers for the isolated measurement of ac. or d.c. currents. Based on the principle of Hall effect and null balance method. Small footprint Measures dc, ac and impulse currents Large primary conductor hole ...
Current sensors for electronic measurement of alternating, direct, ...
Description:
Current sensors for electronic measurement of alternating, direct, pulse and mixed currents with galvanic insulation between the primary circuit (strong current) and secondary circuit (electronic circuit)Hall Effect measuring principle.Used with AC variable speed drives, static converters for DC motor drives, ...