Phoenix Contact PACT RCP-4000A-1A-D190 Series Current Sensor, 100 → 4000A, 0 → 1A output current

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PACT RCP - Current Transformer

The PACT RCP Current Transformer Kit for retrofitting for alternating currents up to 4000 Aac.

Current Transformer Kit

Kit consisting of 2 components: 1 A measuring transducer and a Rogowski coil
High system availability due to easy installation without removing system parts
Transform alternating currents up to 4000 A using a single measuring system
Space saving and handy: the current strength does not affect the size and weight of the coil
Safe installation and operation: no dangerous open circuit voltages
Harmonics and transients detected with phase accuracy with a large frequency range from 10 to 5000 Hz
Rogowski coil secured on power rails and circular conductors, plus high measuring accuracy, thanks to rofessional holding device
A holder for the coil is also available (stock-no.: 820-0447)

Measuring Transducer

Measuring transducer processes the mV signal of the upstream Rogowski coil
8 current measuring ranges (100 - 4000 Aac) which can be set via DIP switches
Max. output current of 1 Aac
Power supply 19.2 – 30 Vdc
Power consumption 4W

Rogowski Coil

The Rogowski coil is used for AC current measurement for busbars and power lines
The coil is available in different length and diameters:
Length: 300 mm, diameter when installed: 95 mm, stock-no.: 820-0431
Length: 450 mm, diameter when installed: 140 mm, stock-no.: 820-0435
Length: 600 mm, diameter when installed: 190 mm, stock-no.: 820-0444

Holder

The optional holder ensures the Rogowski coil is securely seated on busbars with a thickness of 5-15 mm
During installation, the coil housing is pushed onto the flange of the holding device and snaps in automatically
Stock-no is 820-0447

Phoenix Contact Current Transducer

Specifications
Attribute Value
Output Current Range 0 → 1A
Nominal Current 100 → 4000A
Supply Voltage 24 V dc
Mounting Type Flange Mount
Frequency Bandwidth 10 → 5000 Hz, 45 → 65 Hz
Accuracy ±0.21 %
Bore Size 8.3mm
Series PACT RCP-4000A-1A-D190
Minimum Operating Temperature -30°C
Maximum Operating Temperature +80°C
Depth 85mm
Height 70.4mm
Width 22.5mm
3 In stock for delivery within 2 working days
Unit of sale: Each
258.40
(exc. VAT)
317.83
(inc. VAT)
units
Per unit
1 - 4
€258.40
5 +
€250.52
Related Products
TLI4970 high-precision current sensors from Infineon are based ...
Description:
TLI4970 high-precision current sensors from Infineon are based on their Hall technology They are straight-forward, fully digital solutions which do not require external calibration or extra parts to function. Their compact footprint is also made possible by a coreless technology. ...
The CMS2000 current sensor family from Sensitec are ...
Description:
The CMS2000 current sensor family from Sensitec are compact devices offering accurate current measurement They are able to provide measurement for AC, DC and mixed currents featuring integrated galvanic isolation.Designed for industrial applications, the CMS2000 current sensors are based on ...
Passive current transformers without auxiliary power Convert ac ...
Description:
Passive current transformers without auxiliary power Convert ac into analogue signals 1 to 20mA or 0 to 10VLimit monitor Limit value and alarm suppression time set by two potentiometers1 NO, 1NC relay contact
AC / DC transformer with integrated signal preparation ...
Description: