HOBUT DIN Rail Mounted Circuit Transformer, -30 → +85 °C, 21mm diameter , 40:5

  • RS Stock No. 331-597
  • Mfr. Part No. CT132M40/5-1/3
  • Manufacturer HOBUT
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

HOBUT Current Transformer

The HOBUT 13 series moulded case current transformer with UKAS calibrated is compact and suitable for primary currents from 40A to 300A with built-in sealable terminal covers. It is used for transforming various primary currents into 5A standard secondary using up to 20mm diameter cables. The system voltage ranges between 0.72kV and 3kV and a current ratio of 50:5.
CT Class Information for Series 16
331-395 - Class 1
331-547 - Class 1
331-373 - Class 0.5
331-367 - Class 0.5
331-446 - Class 0.5

Features and Benefits

Built in sealable terminal covers
Continuous current: 1.2 x rated current
DIN rail mounting clip supplied
Mounting feet supplied
21mm aperture
Overall depth of 30mm, height of 65mm and width of 45mm
Operating temperature ranges between -30°C and 85°C

Certifications

CE certified
IEC185
BS 7626
BSEN 60044-1
IEC 60044-1
ANSI/ESD S20.20:2014
BS EN 61340-5-1:2007

Specifications
Attribute Value
Current Ratio 40:5
Inner Diameter 21mm
Transformer Type DIN Rail Mounted
Overall Height 65mm
Overall Width 45mm
Overall Depth 30mm
Minimum Temperature -30°C
Maximum Temperature +85°C
20 In stock for delivery within 2 working days
Unit of sale: Each
14.01
(exc. VAT)
17.23
(inc. VAT)
units
Per unit
1 - 4
€14.01
5 - 9
€13.59
10 +
€13.29
Related Products
Power consumption 25VA, 50/60Hz Accuracy class 120 or ...
Description:
Power consumption 25VA, 50/60Hz Accuracy class 120 or 30mm busbar mounting Suitable for circular conductors 24 aperture Maximum aperture for bar conductors 30x10mm (type 6)Operating temperature range –30 to +85°CSecondary terminals M5 studs with lock washers, nuts and terminal cover ...
CT’s are square type and encapsulated with polycarbonate ...
Description:
CT’s are square type and encapsulated with polycarbonate These metering CT’s feature sealable terminal covers and a wide range of primary current ratings. Available in various, Bus bar sizes, case widths, and mounting options. Comprehensive class accuracy Cost effective moulded ...
Three phase measuring current transformers suitable for primary ...
Description:
Three phase measuring current transformers suitable for primary ranges from 60A to 630A with 5A secondary Allowing installations directly next to the moulded case circuit breakers for greater speed of installation and optimisation of space. Applicable to MCCB such as ...
Set consisting of one 1 A measuring transducer ...
Description:
Set consisting of one 1 A measuring transducer and one UV-resistant Rogowski coil with signal line Length of Rogowski coil: 600 mm, diameter: 190 mm. Length of signal line: 3 m. The Rogowski coil measures the AC current of busbars ...