HOBUT Clip Fit Circuit Transformer, -30 → +80 °C

  • RS Stock No. 533-0621
  • Mfr. Part No. CTSCEN200<1000/5
  • Manufacturer HOBUT
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Split-core Current Transformer

Two multi-ratio split-core current transformers with four or five built-in current ratios in one product

Can be installed into existing systems without disconnecting cables or busbar connections
Suitable for use with analogue, digital and energy meters
Accuracy class 1 (±1%)
Ambient temperature range: -30°C to 80°C
Frequency range: 50-60Hz
Insulation rating: 3kV for 1 minute
Continuous current: 1.2 x rated current

//media.rs-online.com/t_line/L533062-01.gif

Current Transformers

Specifications
Attribute Value
Current Ratio 200:5, 400:5, 600:5, 800:5, 1000:5
Transformer Type Clip Fit
Overall Height 125mm
Overall Width 132mm
Overall Depth 38mm
Minimum Temperature -30°C
Maximum Temperature +80°C
1 Within 1 working day(s) (IE stock)
13 Within 2 working day(s) (EU stock)
Unit of sale: Each
73.01
(exc. VAT)
89.80
(inc. VAT)
units
Per unit
1 - 4
€73.01
5 - 9
€70.77
10 +
€69.24
Related Products
Power consumption 25VA, 50/60Hz Accuracy class 120 or ...
Description:
Power consumption 25VA, 50/60Hz Accuracy class 120 or 30mm busbar mounting Suitable for circular conductors 24 aperture Maximum aperture for bar conductors 30x10mm (type 6)Operating temperature range –30 to +85°CSecondary terminals M5 studs with lock washers, nuts and terminal cover ...
OMEGA 3 Phase current transformers are suitable for ...
Description:
OMEGA 3 Phase current transformers are suitable for primary ranges from 60 A to 630 A with 5 A secondary The current transformers allow faster installation directly next to the moulded case circuit breakers for optimised use of space. • ...
Three built-in fixing methods: Base and DIN rail ...
Description:
Three built-in fixing methods: Base and DIN rail mounting Case moulded in impact polyester with built-in hinged terminal cover Cables up to 14mm outside diameter, or a busbar 14mm wide Accuracy Class 1 (60 & 80A) or Class 3 (25 ...
Split current transformers with unique clip-together feature enabling ...
Description:
Split current transformers with unique clip-together feature enabling high speed permanent installation Can be installed into existing networks without disconnecting cables or busbars Ambient temperature range: -30°C to 80°CFrequency range: 50-60Hz Insulation voltagel: 3kV for 1 minute Continuous current: 12 ...