Eaton 11 kW Automatic 3P DOL Starter, 400 V ac, IP65

  • RS Stock No. 528-7432
  • Mfr. Part No. XDP11/I(400V50HZ)
  • Manufacturer Eaton
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): GB
Product Details

EATON XDP DOL Starter Series with Isolator

Providing reliability and long operating life, these 'direct-on-line' starters are totally insulated with IP65 protection. Capable of high numbers of operations, these starters are constructed from standard components meaning they are very easy to maintain. Fitted with AC-3 rated triple pole contactor, AC-3 rated triple pole switch disconnector and on and off pushbuttons, these devices also allow for 3 padlocks for additional safety.

All starters in this range are wired to accept EATON overload relays for overload protection, also available from RS components to be purchased separately.
4 & 5.5kW models = H200 x W120 x D160mm, 7.5 & 11kW models = H240 x W160 x D160mm

Features and Benefits:

• Fitted with metric knockouts
• Easy maintenance
• Complies with IEE regulations
• 16th edition on isolation and switching
• Glass fibre reinforced polycarbonate casing

Applications:

Used for starting 3 phase induction motors, direct on line starters are regularly used in industrial applications such as conveyor belts, compressors and small water pumps.

What is the difference between dol and star delta starters?

Both devices are used to start induction motors however, where partial voltage is applied to each winding of a star delta starter, a DOL has 100% voltage applied. This also applies to the current, a star delta uses one-third of the starting current that a DOL does. Direct on line starters are the most common and simplest starting method, within a motor start-up they also provides the lowest temperature rise. Star delta starters allow for starting the motor at a lower voltage, making them suitable for high inertias.

Note

FLC figures quoted are maximum, other overload ratings can be used dependant on FLC rating.

Standards

IEC/EN 60529, DIN 43660, EN 50262

Specifications
Attribute Value
Power Rating 11 kW
Motor Starter Type DOL
Voltage Rating 400 V ac
IP Rating IP65
Number of Poles 3P
Motor Starter Functionality Automatic
Additional Features Disconnect Switch Included
Overall Length 240mm
Enclosure Yes
Overall Width 160mm
Overall Depth 160mm
Series XDP
2 In stock for delivery within 2 working days
Unit of sale: Each
179.97
(exc. VAT)
221.36
(inc. VAT)
units
Per unit
1 +
€179.97
Related Products
Approvals: CSA, UL, NEMKO, DEMKO, SEMKO, FIMKO 'Type ...
Description:
Approvals: CSA, UL, NEMKO, DEMKO, SEMKO, FIMKO 'Type 2’ co-ordination to IEC 947-4-1Choice of control voltage400//415 Vac Supplied with 1 N/O auxiliary contact for contactor & 1 N/O + 1 N/C auxiliary for circuit breaker Coil terminal at bottomDIN rail ...
The Te Sys U is a modular system ...
Description:
The Te Sys U is a modular system for motor control; it enables the user to create a customised solution for their control requirements, from a series of standard modules The plug-in modules allow the assembly and wiring before the ...
One-directional direct starter for controlling motors up to ...
Description:
One-directional direct starter for controlling motors up to 11 kWThermal relay to be ordered separately.Control using two buttons mounted on the box cover.Mounting layout is different compared to the older product.Empty housing is used exclusively with models LE1-D09 and LE1-D12. ...
Enclosed starters with isolation device An LA2 DS2 ...
Description:
Enclosed starters with isolation device An LA2 DS2 timer imposes a delay of 40 ms ± 15 ms on the delta contactor at the moment of changeover to ensure that the star contactor has sufficient breaking time. Maximum operating rate: ...