Fluke 1630-2 FC Earth & Ground Resistance Tester 1500Ω CAT III 1000 V, CAT IV 600 V RS Calibration

  • RS Stock No. 136-5143
  • Mfr. Part No. FLUKE-1630-2 FC
  • Manufacturer Fluke
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): CN
Product Details

Fluke 1630-2 FC Earth Ground LeakageTester

This 1630-2 FC offers a stakeless earth ground loop and ac leakage clamp, with Fluke Connect. Which identifies ground loop impedance without having to disconnect the ground from the grounding system, and without having to use auxiliary test stakes. Save and share data via Fluke Connect® wireless test system.

Fluke Connect® Wireless System

The 1630-2 FC supports the Fluke Connect Wireless System (may not be available in all regions). Fluke Connect wirelessly connects the clamp with an app on your smartphone or tablet. The app shows the ground resistance measurements on your smartphone or tablet display. You can save these measurements, GPS location from your phone and images to Fluke Connect Cloud storage and share with your team.

Feature and Benefits

• High-quality • Rugged
• Identify ac leakage currents without disconnecting the earth ground stake from the grounding system
• Ideal for system troubleshooting
• Heavy-duty clamp jaw stays in alignment and in calibration even in every day, on-the-job industrial environments
• The earth grounding clamp saves time by automatically recording data at pre-set intervals and saves up to 32760 measurements in memory at the set logging interval
• User-defined high/low alarm limits, for rapid measurement evaluation
• Selectable band-pass filter function removes unwanted noise from the ac leakage current measurement

Fluke Earth & Ground Resistance Tester

The Fluke earth and ground resistance tester measures a 1.5kΩ absolute maximum resistance and having the CAT III 1000V, CAT IV 600V safety category. It offers a stakeless earth ground loop and AC leakage clamp. It identifies ground loop impedance without disconnecting the ground from the grounding system and without having to use auxiliary test stakes, save and share data via Fluke Connect® wireless test system. Fluke Connect wirelessly connects the clamp with an app on your smartphone or tablet. The app shows the ground resistance measurements on your smartphone or tablet display. You can save these measurements, GPS location from your phone and images to Fluke Connect cloud storage and share with your team.

Features and Benefits

• Heavy-duty clamp jaw stays in alignment and in calibration even in everyday, on-the-job industrial environments
• High quality
• Ideal for system troubleshooting
• Identify AC leakage current without disconnecting the earth ground stake from the grounding system
• Rugged
• Selectable band-pass filter function removes unwanted noise from the AC leakage current measurement
• The earth grounding clamp saves time by automatically recording data at pre-set intervals and saves up to 32760 measurements in memory at the set logging interval
• User-defined high/low alarm limits for rapid measurement evaluation

Certifications

• CE certified
• CSA certified
• IC certified
• IEC/EN 60529
• IP30 rated

Specifications
Attribute Value
Absolute Maximum Resistance Measurement 1500Ω
Calibrated RSCAL
Best Accuracy ±1.5 % of 0.02 Reading
Display Type LCD
Safety Category CAT III 1000 V, CAT IV 600 V
Battery Life 15 h
Battery Type 1.5 V AA Alkaline IEC/EN LR6
Power Source Battery
Dimensions 105 x 48 x 283mm
Weight 880g
Height 283mm
Includes Earth Ground Clamp, Hard Case, Loop Resistance Standard, Quick Reference Guide, Safety Information Guide, 4 AA Batteries
Length 105mm
Maximum Operating Temperature +50°C
Measurement Type Earth Ground Loop Resistance
Minimum Operating Temperature -10°C
Safety Category Voltage 600 V, 1000 V
Safety Category Level CAT III, CAT IV
Model Number p 1630-2 FC
Width 48mm
Temporarily out of stock - back order for despatch when stock is available
Unit of sale: Each
1,606.00
(exc. VAT)
1,975.38
(inc. VAT)
units
Per unit
1 +
€1,606.00
Related Products
Kits for performing tests required by NF C ...
Description:
Kits for performing tests required by NF C 15-1001 DT-170 (differential controller)1 DT-300 (earth and continuity measuring device and extension cord)1 M-9955538 (diagnostic book 15-100)1 DT-500* (Insulation controller and connectors)
Tester for complete and rapid appraisal of earthsMulti-function ...
Description:
Tester for complete and rapid appraisal of earthsMulti-function measurement:Earth resistance, earth coupling, soil resistivity and continuity/resistance.Ergonomic:Rugged, watertight field enclosure with giant backlit LCD display.Direct access to measurements by selector switch.Battery can be recharged from mains ...
DET24C Additional Features Ground resistance range : 0.050 ...
Description:
DET24C Additional Features Ground resistance range : 0.050 Ω to 1500 ΩTrue RMS Ground leakage current range : 0.2 mA to 35 AAuto ranging & HOLD function4 digit plus 6 digit backlit LCD display High and low resistance alarms256 test ...
DET24C is a clamp-on ground resistance tester that ...
Description:
DET24C is a clamp-on ground resistance tester that set new standards in terms of access, performance, features, simplicity of operation and safety The units are designed with flat core ends to prevent dirt build-up, ensuring measurement integrity and improved reliability ...