Tektronix, MDO4104C+MDO4SA3 Mixed Domain Oscilloscope, 1GHz, 4 Analogue. Ch.

  • RS Stock No. 908-4962
  • Mfr. Part No. MDO4104C+MDO4SA3
  • Manufacturer Tektronix
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CN
Product Details

Tektronix Mixed Domain Oscilloscopes MDO4000C Series with Spectrum Analyzer

The Tektronix MDO4000C Series offers up to 1GHz sample rate, whilst delivering debug features, selectable record length and a full suite of automated measurements with 4 analog channels and 16 digital channels. The MDO4000C uses an integral Spectrum Analyzer providing 9KHz-3GHz (suffix +MDO4SA3) or 9KHz-6GHz (Suffix +MDO4SA6) of spectrum acquisition. The spectrum analyser provides simultaneous synchronised acquisition of analog, digital and spectral signals, making them useful for incorporating wireless communications (IoT) and EMI troubleshooting.

The spectrum analyzer offers 4 different traces or views:

Normal

Average

Max Hold

Min Hold

Key Benefits

Embedded Design

Ability to discover and solve issues swiftly with a system debug on mixed-signal embedded systems including most common serial bus and wireless technologies.

Power Design

The widest selection of power probes allows for reliable and repeatable voltage, current and power measurements using an automated power quality, switching loss and harmonics, ripple, modulation and safe operating area measurements.

EMI troubleshooting

Narrows down the source of EMI within an embedded system by determining which time domain signals may be causing unwanted EMI.

Manufacturing Test and Troubleshooting

The MDO4000C has a unique 6 in 1 that minimizes rack or bench space through integrating six instruments in one single instrument. It reduces the cost associated with syncing multiple different instrument types.

Key Features

4 analog channels

20Mpts record length on all channels

Integral spectrum analyzer

Integral 4-digit digital voltmeter (DVM) and 5-digit frequency counter

Standard ports: Ethernet, VGA, USB host (2) and device, AUX OUT, REF IN and AFG output, VESA and Kensington lock interfaces

10.4 in XGA 1024 x 768 display with automatic dimming

Dimensions 229 x 439 x 147 mm (9 x 17.3 x 5.8 in)

FAQ's

Q. Why choose Mixed Signal Oscilloscope?

A. A key advantage to a Mixed Signal Oscilloscope (MSO) is that you use it in a similar way to a normal Oscilloscope however, an MSO allows for multiple time-aligned digital and analogue waveforms to be presented in a single display. This enables the operation of embedding a circuit for analysing.

Q. What is a Mixed Signal Oscilloscopes used for?

A. Mixed Signal Oscilloscopes not only capture digital and analogue signals, but they're a measurement application for verifying and debugging. Used in almost the same way as an oscilloscope and combines the measurement capabilities found in a logic analyzer. Used in a broad range of consumer and industrial applications.0 of spectrum acquisition.

Note

Accessories available separately include GPIB to USB adapter TEK-USB-488 ( 113-143 ) & rack mount kit RMD3000 ( 697-8794 ). Probes available separately include: TPP0500B replacement passive probe ( 797-3390 ) for ≤500 MHz models; TPP1000 replacement passive probe ( 728-6759 ) for 1 GHz models; TPP0502 ( 734-5016 ) passive probe; TPP0850 (734-5010 ) & P5100A ( 734-5013 ) high-voltage passive probes; TAP1500 ( 661-3286 ), TAP2500 ( 232-288 ) & TAP3500 ( 668-7155 ) active probes; TCP0030A ( 781-0807 ) & TCP0150 ( 661-3283 ) current probes; TDP0500 ( 661-3292 ), TDP1000 ( 668-7167 ) & TDP1500 ( 668-7161 ) differential probes; THDP0200 ( 752-7357 ), THDP0100 ( 752-7353 ) & P5200A ( 734-5029 ) high-voltage differential probes; P6616 ( 728-6753 ) logic probe. Application modules available separately include: DPO4AUDIO ( 727-6695 ); DPO4AUTO ( 728-6706 ); DPO4AUTOMAX ( 728-6709 ); DPO4COMP ( 728-6703 ); DPO4EMBD ( 728-6712 ); DPO4ENET ( 728-6734 ); DPO4USB ( 728-6715 ); DPO4PWR ( 728-6719 ); DPO4LMT ( 728-6731 ) & DPO4VID ( 728-6728 ).

Supplied with

Passive probe (1 per analog channel), front cover, accessory bag, installation and safety instructions, printed manual (English, French, Japanese, Simplified Chinese), power cord, OpenChoice® desktop software (on CD), calibration certificate

Mixed Domain Oscilloscopes

Specifications
Attribute Value
Bandwidth 1GHz
Number of Analogue Channels 4
Number of Digital Channels 16
Calibrated UKAS
Record Length 20M points/ch
Sample Rate Random 2.5 G samples/s
UART Interface Yes
USB Interface Yes
Vertical Resolution 8 bit
Maximum Time Base 1000s
Minimum Vertical Sensitivity 1mV/div
Maximum Vertical Sensitivity 10V/div
Height 229mm
Model Number p MDO4104
SPI Interface Yes
IIC Interface Yes
Maximum Operating Temperature +50°C
Dimensions 439 x 147 x 229mm
RS485 Interface Yes
Safety Category Level CAT II
RS422 Interface Yes
Minimum Operating Temperature 0°C
Input Capacitance 3.9 pF
Screen Size 264mm
Safety Category CAT II 300 V
Rise Time 350ps
Weight 5kg
Input Impedance 1 MΩ
Safety Category Voltage 300V
CAN Interface Yes
Lin Interface Yes
Display Type TFT LCD
RS232 Interface Yes
Length 439mm
Width 147mm
Power Source Mains
Temporarily out of stock - back order for despatch when stock is available
Unit of sale: Each
21,440.00
(exc. VAT)
26,371.20
(inc. VAT)
units
Per unit
1 +
€21,440.00
Related Products
The Keysight Technologies Infinii Vision 3000T X-Series 1GHz ...
Description:
The Keysight Technologies Infinii Vision 3000T X-Series 1GHz mixed-signal oscilloscope offers an extremely intuitive 85in capacitive touch user interface with zone touch triggering. This product has 4 analogue and 16 digital channels. It simplifies navigation, facilitates documentation and increases productivity, ...
Bandwidth is upgradable (up to 1 GHz)Up to ...
Description:
Bandwidth is upgradable (up to 1 GHz)Up to 5 GS/s sample rate10 M record length on all channels>280,000 wfm/s maximum waveform capture rate Standard passive voltage probes with 39 pF capacitive loading and 250 MHz or 500 MHz analog bandwidth ...
Bandwidth is upgradable (up to 1 GHz)Up to ...
Description:
Bandwidth is upgradable (up to 1 GHz)Up to 5 GS/s sample rate10 M record length on all channels>280,000 wfm/s maximum waveform capture rate Standard passive voltage probes with 39 pF capacitive loading and 250 MHz or 500 MHz analog bandwidth ...
Keysight Infinii Vision 2000 & 3000 X-Series offers ...
Description:
Keysight Infinii Vision 2000 & 3000 X-Series offers the power of 4 instruments in 1: oscilloscope; logic analyzer; function generator; protocol analyzer The models are fully upgradable (bandwidth, MSO, Wave Gen, memory, measurement applications) to meet future requirements and protect ...