Unipower 40 A Motor Load Monitor, 100 400 V ac

  • RS Stock No. 745-8030
  • Mfr. Part No. HPL500
  • Manufacturer Unipower
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DK
Product Details

HPL500 Digital Motor Load Monitor

The HPL500 replaces the HPL420 and also incorporates many new features, however it has been designed so that users of the HPL420 will be familiar with its set-up procedure. The display is used as a reference enabling true motor load, trip levels and all other variables to be displayed and programmed quickly and accurately using only three push buttons. For two speed motor applications an input allows the application to select the active limit
The HPL500 is usually mounted in the motor control panel and is connected to a convenient point on the motor supply (before Inverter - if used).
Therefore no external field wiring or sensors in the equipment are necessary. In addition to displaying true motor power in real time the units capture and, on demand, display the instantaneous minimum and maximum power levels to assist in setting up trip limits and fault diagnosis. The HPL500 features a current feed-through tube for measuring continuous motor currents up to 40 amps, (27.7kW at 3 x 400vac). Therefore no Current Transformer is required unless the motors continuous current exceeds 40A.
A specially designed power supply (Patent Pending) allows the motor voltage to be programmable from 100 – 400vac single phase and 100 – 575vac 3-phase making the HPL500 suitable for world-wide use.
The 0(4)-20ma analogue output, which is proportional to motor load, can be scaled to the range of measured power and can be inverted for use in closed loop control systems.

Measures true motor load in kW (√3 x I x V x Cosφ) and futures a digital display of kW% and kW, and programmable trips for over and/or under load events
Can be programmed to calculate Shaft Output Power P2 if required
Protects equipment from damage caused by the motor running against a jam, blockage or under load
Used in processes to trigger actions when predetermined load levels are reached (end point monitoring)
Three digital delay timers, programmable from 0.1-99.9 seconds are incorporated to time out motor start surge and short duration over and under power events which could cause nuisance tripping
Two output relays are individually programmable, over or under-load alarms
Output relay state (NO or NC) can also be programmed
All settings are key-lock protected
Used for the over/under load protection of: Pumps (dry run, closed valve), Fans (broken belt, closed damper), Conveyors (screw and belt) Separation screens, Macerators, Scrapers, Mechanical drives (gearboxes, chains)
Also suitable for Process Control, PLC and SCADA input

Approvals

CE, UL and GOST-R

Specifications
Attribute Value
Motor Protection Component Load Monitor
Output 3
Sensing Type Current Transformer
Supply Voltage 100 400 V ac
Current Rating 40 A
Control Voltage 100 575 V
Enclosure Type Din Rail, Wall Mount
Series HPL
22 In stock for delivery within 2 working days
Unit of sale: Each
704.87
(exc. VAT)
866.99
(inc. VAT)
units
Per unit
1 +
€704.87
Related Products
The network-capable 3-phase hybrid motor starter with reversing ...
Description:
The network-capable 3-phase hybrid motor starter with reversing function and current monitoring The amount of cabling required is reduced to a minimum by the internal locking circuit and the load wiring The control commands for backward and forward running are ...
Zero Stacking - compact design and mounting drives ...
Description:
Zero Stacking - compact design and mounting drives side by side with no air gap saves valuable panel space Integrated EMC filter for out-of-the-box performancePC Tools such as Drive Explorer™ are available to assist with programming, monitoring and troubleshooting Software ...
The Altivar ATV12 Series is made up from ...
Description:
The Altivar ATV12 Series is made up from Variable Speed Drives for small machines with a three-phase 240 V 0 18 to 4 kW asynchronous motors. This type of VFD has a low voltage, high performance and excellent power. The ...
Quantifying the status of a three-phase induction motor ...
Description:
Quantifying the status of a three-phase induction motor and pump The alarm output threshold default is set. You can customize the value according to the site. As for comprehensive current diagnosis, the degradation can be detected comprehensively by combining each ...