Pico Technology Oscilloscope Probe, Probe Type: Active, Differential 100MHz 1kV 1:100, 1:1000

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): TW
Product Details

Pico Technology Oscilloscope Probe

The Pico Technology TA042 oscilloscope probe is an active differential probe, suitable for high common-mode voltage measurement applications up to ±1400V. It can be used with a signal speed of up to 100MHz. This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high voltage differential measurements.

Features and Benefits

Bandwidth is DC to 100MHz (–3dB)
Attenuation ratio is 100:1/1000:1
Accuracy is ±2%
Input impedance is 4Mohm ll7pF each side to ground
Differential range is (100:1) ±140V (DC + peak AC) or 140VRMS
Maximum differential is (100:1) ±1400V (DC + peak AC) or 1000VRMS
Common mode range is ±1400V (DC + peak AC) or 1000VRMS (1/100 & 1/1000)
Absolute maximum voltage is ±1400V (DC + peak AC) or 1000VRMS CAT III (1/100 & 1/1000)
Swing is ±7V into 50Kohm load
Offset (typical) is <±5mV
Noise (typical) is 0.9mVRMS
Source impedance is 50
CMRR (typical) is 80dB at 60Hz and 50dB at 1MHz
Ambient operating temperature ranges between -10°C and 40°C
Power requirement 4xAA cells or 6VDC/200mA mains adaptor or regulated 9VDC/120mA mains adaptor

Applications

Safe measurement in power circuit
Acquisition of low speed balanced differential signals found in serial communications buses
Transients in switching power supplies, inverters and motor drives, electronic ballasts and CRT displays
Signals in the milliV range from sensors and other instrumentation

Certifications

IEC-1010.1
IEC-1010.2-031 CAT III
Pollution Degree 2.

Specifications
Attribute Value
Probe Type Active, Differential
Attenuation 1:100, 1:1000
Bandwidth 100MHz
Maximum Common Mode Input Voltage 1kV
Number of Probes 2
Safety Category Level CAT III
Safety Category Voltage 1000 Vrms, 1400 V ac/dc
Safety Category CAT III 1400 V ac/dc, 1000 Vrms
Rise Time 3.5ns
15 In stock for delivery within 2 working days
Unit of sale: Each
519.00
(exc. VAT)
627.99
(inc. VAT)
units
Per unit
1 +
€519.00
Related Products
Bandwidth DC-70 MHz Rise time ≤5 nsDC accuracy ...
Description:
Bandwidth DC-70 MHz Rise time ≤5 nsDC accuracy ±2%Attenuation ratio 50 X/500 XMaximum differential test voltage (DC + Peak AC) 50 X: 150 V, 500 X: 1500 VMaximum input common mode voltage (voltage-to-earth Vrms) 600 V CATIII, 1000 V CATIIInput ...
The Teledyne Le Croy oscilloscope probe is affordable ...
Description:
The Teledyne Le Croy oscilloscope probe is affordable and optimally designed for measurement of small signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD and RF immunity testing sensor monitoring It far surpasses the ...
The Digilent BNC terminated oscilloscope probe is perfect ...
Description:
The Digilent BNC terminated oscilloscope probe is perfect to use with the Analogue Discovery™ in conjunction with the Discovery BNC adapter Bandwidth for 1x DC to 6MHz and 10x DC to 100MHz Selectable 1X/10X input attenuation Input resistance is 1x1Mohm ...
The Tektronix single-ended Active FET oscilloscope probe provides ...
Description:
The Tektronix single-ended Active FET oscilloscope probe provides excellent high-speed electrical and mechanical performance required for digital system designs It is specifically designed for direct connection to oscilloscopes with the TekVP probe interface.Note:TAP1500 includes individual probe case Supplied ...