12V ac 2 Output Through Hole PCB Transformer, 10VA

  • RS Stock No. 347-2616
  • Mfr. Part No. VC 10/2/12
  • Manufacturer Block
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

PCB Mount 230Vac Primary VC/VCM Series

Single and twin secondary windings for series or parallel connection
Vacuum resin moulded to UL94-V0 rating
Low inter-winding capacitance
Low radiated noise
100% electrical and flash tested
Extra fixing points for secure board mounting (25 VA and 36 VA)

Note

To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series.

Standards

EN 61 558 IEC 61558

Approvals

ENEC, UL recognised

//media.rs-online.com/t_line/L347247-01.gif
//media.rs-online.com/t_line/L347248-01.gif

Approvals

VDE; UL

Standards

EN 61 558; IEC 61558

Specifications
Attribute Value
Secondary Voltage Rating 12V ac
Power Rating 10VA
Primary Voltage Rating 230V ac
Number of Outputs 2
Length 51mm
Width 34.6mm
Depth 43mm
Dimensions 51 x 34.6 x 43mm
Weight 280g
Mounting Type Through Hole
Maximum Temperature +40°C
26 In stock for delivery within 2 working days
Unit of sale: Each
9.85
(exc. VAT)
12.12
(inc. VAT)
units
Per unit
1 - 9
€9.85
10 - 24
€9.38
25 - 49
€8.64
50 +
€7.86
Packaging Options:
Related Products
Chassis mounting low voltage mains transformers with a ...
Description:
Chassis mounting low voltage mains transformers with a single 230Vac. 50/60Hz primary winding. The two independent secondary windings may be connected in series or parallel to give a wide range of output voltage and current options. Double section bobbin construction ...
Twin 115Vac. 50 to 60Hz primary windings for ...
Description:
Twin 115Vac. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins100% electrical and ...
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional ...
Secondary voltages are nominal load voltages on resistive ...
Description:
Secondary voltages are nominal load voltages on resistive loads