SP-NC Reed Relay, 2 A, 5V dc

  • RS Stock No. 124-5090
  • Mfr. Part No. DBT70510-HR/RS
  • Manufacturer Cynergy3
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): GB
Product Details

Cynergy 3 - Reed Relay D-HR Series

Cynergy 3 reed relays have high isolation voltages. These are ideal for applications such as cardiac defibrillators, test equipment and high voltage power supplies.

Features and Benefits

Low contact resistance
10kV ot 15kV isolation
Minimum insulation resistance 1 x 1014
PCB or flying leads connections

Note

The rhodium contact relays have low contact resistance, the tungsten contact relays can switch to higher voltages.

Standards

ISO 9001

Cynergy 3 - Reed Relay D-HR Series

Specifications
Attribute Value
Contact Configuration SP-NC
Coil Voltage 5V dc
Mounting Type PCB Mount
Maximum Switching Current AC 2 A
Maximum Switching Current DC 2 A
Maximum Switching Voltage AC 1000V
Maximum Switching Voltage DC 1000V
Coil Resistance 38 Ω
Length 60mm
Height 18.5mm
Depth 15.8mm
Dimensions 60 x 15.8 x 18.5mm
Isolation Coil To Contact 17kV
Maximum Switching Power DC 50 W
Operating Temperature Range -20 → +70°C
Contact Material Tungsten
Maximum Operating Temperature +70°C
Terminal Type PCB Pin
Relay Switching Classification General Purpose Relay
Number of Poles 1
Operating Time Including Bounce 2ms
Minimum Operating Temperature -20°C
Contact Resistance 250 mΩ
Special Features High Insulation Resistance, Low Contact Resistance
Life 1000000 (50 W) operations, 1000000000 (Dry) operations
3 In stock for delivery within 2 working days
Unit of sale: Each
52.31
(exc. VAT)
64.34
(inc. VAT)
units
Per unit
1 +
€52.31
Related Products
The S2 (UL) reed relay series is designed ...
Description:
The S2 (UL) reed relay series is designed for applications where PCB is not possible Mounted in a series of positions the S2 (UL) can be orientated to suit. Flexible leadout wires allow bending for equipment assembly. Variable mounting options ...
Washproof reed relay for DC voltage MonostableFor installation ...
Description:
Washproof reed relay for DC voltage MonostableFor installation in pushdown switches (RM 254 mm)Low contact noise, low thermo voltage Available with shielding plate for electrostatic protection and spark extinguisher / damper diode.
Washproof reed relay for DC voltage MonostableFor installation ...
Description:
Washproof reed relay for DC voltage MonostableFor installation in pushdown switches (RM 254 mm)Low contact noise, low thermo voltage Available with shielding plate for electrostatic protection and spark extinguisher / damper diode.
Encapsulated in a nickel-plated steel case for magnetic ...
Description:
Encapsulated in a nickel-plated steel case for magnetic screening Mechanical Life : 108 Operations Maximum switching current 1A