Merlin Gerin 2 Pole Type A Residual Current Circuit Breaker, 40A RED, 300mA

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IT
Product Details

ID REDs series differential switches

Assembly comprising a two-pole differential switch and a reset for start-up control and protection.
The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.
This device can be deactivated when people are present in the controlled areas.
A 3-mode configurable auxiliary contact is available for remote indication.
Test function possible in manual mode.
Switch status is indicated by two indicator lights on the front panel.

Standards

IEC 61008; EN 61008

Specifications
Attribute Value
Current Rating 40A
Number of Poles 2
Trip Sensitivity 300mA
Tripping Characteristics Type A
Voltage Rating 230V
Series RED
Temporarily out of stock - back order for despatch 13-08-2020, delivery within 2 working days
Unit of sale: Each
352.51
(exc. VAT)
433.59
(inc. VAT)
units
Per unit
1 - 4
€352.51
5 - 9
€341.62
10 +
€337.66
Related Products
For use as spares and replacements in F&G ...
Description:
For use as spares and replacements in F&G Concept 2000 consumer units Manufactured to BS EN 61009Flying lead neutral cable for easy installation Type B MCB and 30mA RCD combined in one device10kA MCB/RCBO breaking capacity Type B MCB/RCBO operating ...
All-current-sensitive FI circuit breaker for detection of residual ...
Description:
All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currents Increased operating reliability in networks with capacitive impedances based on adapted actuation characteristic Switch handle and test button may be locked via handle lock ...
Acti9 iTG40 RCCBs limits wear and reduces voltage ...
Description:
Acti9 iTG40 RCCBs limits wear and reduces voltage drops, helping to prevent premature equipment aging and overheating Visi Trip indicates only the faulty outgoer, allowing fast diagnosis, resolution, and re-closing loads for easier building management and reduced downtime Insulation Voltage: ...
Typical applications include protection of electrical systems of ...
Description:
Typical applications include protection of electrical systems of passenger cars, trucks, buses, watercraft and extra-low voltage wiring systems Particularly suitable for installation in difficult-to-access locations. With reset button and manual release facility Service short-circuit breaking capacity 300 ...