Siemens 4 Pole Type A Residual Current Circuit Breaker, 63A 5SM3, 300mA

  • RS Stock No. 395-878
  • Mfr. Part No. 5SM3646-6KL
  • Manufacturer Siemens
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

5SM3 Series, Undelayed Type A, 4-pole, Left-Side N Connection

RCCB for alternating and pulsating DC residual currents
Option for power connection from above or below
Tunnel terminals with wire protection on both sides
Combination terminal at the bottom for simultaneous connection of busbars and conductors
Safe for fingers and overhands according to DIN EN 50274 (VDE 0660 part 514)
Mounts to DIN rail (TH 35 to DIN EN 60715)
Behind-panel depth 70 mm

Standards

IEC/EN 61008-1, IEC/EN 61008-2-1, IEC/EN 61543

Approvals

VDE 0664-10, VDE 0664-11, VDE 0664-30

Approvals

VDE 0664-10, VDE 0664-11, VDE 0664-30

Standards

IEC/EN 61008-1, IEC/EN 61008-2-1, IEC/EN 61543

Siemens FI circuit breaker

Specifications
Attribute Value
Current Rating 63A
Number of Poles 4
Trip Sensitivity 300mA
Tripping Characteristics Type A
Voltage Rating 400V
Series 5SM3
Temporarily out of stock - back order for despatch when stock is available
Unit of sale: Each
125.24
(exc. VAT)
154.05
(inc. VAT)
units
Per unit
1 - 4
€125.24
5 - 14
€120.18
15 +
€114.98
Related Products
For use as spares and replacements in F&G ...
Description:
For use as spares and replacements in F&G Concept 2000 consumer units Manufactured to BS EN 61009Flying lead neutral cable for easy installation Type B MCB and 30mA RCD combined in one device10kA MCB/RCBO breaking capacity Type B MCB/RCBO operating ...
These devices complement our range of MK Series ...
Description:
These devices complement our range of MK Series enclosures Manufactured to BS EN 61009 Type B MCB and 30mA RCD combined in one device Flying leads for easy installation Positive contact status indication One module wide.
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protectionThe integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
Acti9 iTG40 RCCBs limits wear and reduces voltage ...
Description:
Acti9 iTG40 RCCBs limits wear and reduces voltage drops, helping to prevent premature equipment aging and overheating Visi Trip indicates only the faulty outgoer, allowing fast diagnosis, resolution, and re-closing loads for easier building management and reduced downtime Insulation Voltage: ...