ABB 4P Pole Type AC Residual Current Circuit Breaker, 25A F200, 30mA

  • RS Stock No. 183-3636
  • Mfr. Part No. 442041
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IT
Product Details

The RCCBs F200 series assures protection to people and installations against fault current to earth. A large offer for standard instantaneous and selective AC and A types is completed with some configurations for special applications. This product is suitable for installations where neutral on the left is needed.

Specifications
Attribute Value
Current Rating 25A
Number of Poles 4P
Trip Sensitivity 30mA
Tripping Characteristics Type AC
Voltage Rating 230/400V ac
Series F200
Standards Met IEC/EN 61008-1, IEC/EN 61008-2-1
Circuit Breaker Type RCCB
Reset Actuator Type Toggle Switch
Overall Length 69mm
Overall Depth 85mm
Mounting Style DIN Rail Mount
Breaking Capacity at Maximum Voltage Rating 1 kA
Rated AC Voltage 230/400V
Special Features Protection Against Indirect Contacts and Additional Protection Against Direct Contacts, Protection Against the Effects of Sinusoidal Alternating Earth Fault Currents
Break Time Instantaneous
Terminal Contact Type Screw
Overall Width 70mm
Overall Dimensions 70 x 69 x 85mm
Earth Leakage Protection Type Type AC
2 In stock for delivery within 2 working days
Unit of sale: Each
144.03
(exc. VAT)
177.16
(inc. VAT)
units
Per unit
1 +
€144.03
Related Products
Designed to be used in conjunction with the ...
Description:
Designed to be used in conjunction with the Allen Bradley 100-C contactor range to provide type 2 co-ordination without oversizing of the contactor, in rating up to 22kW The breaker may be customised to suit individual requirements. Trip Class 10Short ...
For use as spares and replacements in F&G ...
Description:
For use as spares and replacements in F&G Concept 2000 consumer units Manufactured to BS EN 61009Flying lead neutral cable for easy installation Type B MCB and 30mA RCD combined in one device10kA MCB/RCBO breaking capacity Type B MCB/RCBO operating ...
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protectionThe integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
All-current-sensitive FI circuit breaker for detection of residual ...
Description:
All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currents Increased operating reliability in networks with capacitive impedances based on adapted actuation characteristic Switch handle and test button may be locked via handle lock ...