Schneider Electric 4 Pole Residual Current Circuit Breaker, 25A iID, 300mA

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): ES
Product Details

RCCB Acti9 iID

The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service.

iID residual current circuit breakers AC Type provide:

Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 100 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).

iID residual current circuit breakers Asi Type provide:

Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 300 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).
Increased immunity from electrical interference and polluted or corrosive environments.

Specifications
Attribute Value
Current Rating 25A
Number of Poles 4
Range Acti 9
Trip Sensitivity 300mA
Series iID
Overall Width 72mm
Circuit Breaker Type RCCB
Rated AC Voltage 415V
Mounting Style DIN Rail Mount
Earth Leakage Protection Type AC
Overall Depth 73.5mm
3 In stock for delivery within 2 working days
Unit of sale: Each
114.58
(exc. VAT)
140.93
(inc. VAT)
units
Per unit
1 +
€114.58
Related Products
SMISSLINE line safety switches with high rated switching ...
Description:
SMISSLINE line safety switches with high rated switching capacity Pluggable in any position Free selection and display of contacting phases (1-pole versions)Pole conductor contacting (L1, L2, L3) visible through inspection window Contact position display visible through inspection window With integrated ...
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protectionThe integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
RCCB for alternating and pulsating DC residual currents ...
Description:
RCCB for alternating and pulsating DC residual currents Option for power connection from above or below Tunnel terminals with wire protection on both sides Combination terminal at the bottom for simultaneous connection of busbars and conductors Safe for fingers and ...
The ABB F200 RCCB Series provide ground fault ...
Description:
The ABB F200 RCCB Series provide ground fault protection by monitoring the leakage of current to ground when used in conjunction with standard MCBs The F200 series are compact DIN rail mounted RCCBs and feature a wide range of trip ...