VALVETRAB® Pluggable single-pole modular lightning surge protector

The 2798844 from Phoenix Contact is a type 2 surge protection plug. This plug is designed to protect low voltage or three phase power supplies in your installations. It's backed with thermal monitoring, easy pluggable design that’s allow for simple maintenance, mechanical indicator that shows the status and a wiring bridge that allows multiple modules to easily connect and be bridged on the ground connection. VALVETRAB provides L-N and L-PEN protection.

Features and benefits:

  • Type 2 with high-capacity varistor for VAL-MS based element

  • For TN/TT systems

  • 230V power supply units according to DIN VDE 0100-534

  • Display to show if the device has an error or damaged

  • Connects in parallel on the mains network and snaps onto a symmetric profile

Accessories:

e 2 base element - 445-5252, 220-3627

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage and current surges depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Specifications
Attribute Value
Suppressor Type Surge Arrester Protection Module
Maximum Voltage Rating 500 V ac
Mounting Type DIN Rail
Maximum Surge Current 30kA
Series VAL-MS
Length 52.4mm
Depth 17.5mm
Height 55.3mm
Dimensions 52.4 x 17.5 x 55.3mm
Minimum Operating Temperature -40°C
Maximum Operating Temperature +80°C
12 In stock for delivery within 2 working days
Unit of sale: Each
81.44
(exc. VAT)
100.17
(inc. VAT)
units
Per unit
1 - 9
€81.44
10 - 24
€77.20
25 - 49
€67.68
50 - 99
€64.25
100 +
€61.08
Related Products
STP T12 25 is the series of combined ...
Description:
STP T12 25 is the series of combined Type 1+2/Class I+II devices for discharging lightning currents and protecting against voltage surges Suitable as the first step of protection in incoming power supply panels and areas with exposure to the atmosphere, ...
Modular surge arrester with Advanced Circuit Interruption (ACI) ...
Description:
Modular surge arrester with Advanced Circuit Interruption (ACI) for single-phase 230 V-TN systems New technology "Advanced Circuit Interruption" (ACI) integrated in the protection module, consists of a switch / spark gap combination Due to ACI technology no external backup fuse ...
Type 1 and 2 prewired spark gap based ...
Description:
Type 1 and 2 prewired spark gap based combined lightning current and surge arresters consisting of a base and plug in modules Maximum system availability and reliability due to the RADAX Flow follow current limitation No tripping of 20amp gL/gG ...
Voltage surges, often referred to as spikes or ...
Description:
Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current ...