Temperature Sensor -10 → +110 °C, -10 → +40 °C, RS PRO, Pipe, PT100

  • RS Stock No. 813-884
  • Manufacturer RS PRO
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): GB
Product Details

Temperature Sensors for Air Conditioning

Thermistor and Pt100 type sensors in a variety of packages suitable for use with most air conditioning control systems.

Sensor Types:
Thermistor: direct thermistor (NTC) temperature (10kΩ at 25°C) versions.
Pt100 sensor: 2 wire sensors with probes providing a linear response and positive temperature coefficient.

Package Types:
Space Air (813-806; 376-1477): a white ventilated unit for interior use, temperature range -10 to +60°C.
Duct Air (813-862): an IP65 housing with 20mm conduit entry, 150x6mm dia. probe, temperature range -30 to +70°C.
Outside Air (813-828; 813-878): an IP65 enclosure with a small caps, 20mm conduit entry, temperature range -30 to +70°C.
Liquid Immersion (813-834; 813-884): an IP65 enclosure with 20mm conduit entry, 150x6mm diameter probe which fits into a pocket (available separately) for a temperature range of -30 to +70°C
Pipe-Clamp on (813-840; 813-890): a sensing element located in a lug which is fitted to the pipe via cable tie. IP65 terminal with 2m of cable, maximum temperature 110°C.

Note

The pockets have grub screw probe fixing for easy replacement.

Specifications
Attribute Value
Application Pipe
Sensing Element Type PT100
Maximum Temperature Sensed +70°C
Minimum Temperature Sensed -30°C
Range of Temperatures Sensed -30 → +70°C
5 Within 1 working day(s) (IE stock)
8 Within 2 working day(s) (EU stock)
Unit of sale: Each
38.15
(exc. VAT)
46.92
(inc. VAT)
units
Per unit
1 - 4
€38.15
5 - 9
€36.99
10 +
€35.39
Related Products
Designed for external contact mounting on hot water ...
Description:
Designed for external contact mounting on hot water cylinders, this unit has a large contact area for good heat transfer Ideal for eliminating boiler short cycling to reduce energy consumption. Also suitable for pipe mounting. Graduated knob for temperature adjustment ...
MCR-FL series temperature measuring transducers for resistance thermometers, ...
Description:
MCR-FL series temperature measuring transducers for resistance thermometers, thermocouples, resistance-type sensors and voltage sensors Freely programmable Loop-powered Two-wire transmitter Pluggable screw connection.
High specification, relative humidity and temperature transmitters for ...
Description:
High specification, relative humidity and temperature transmitters for use with building management systems User configurable for 4-20mA or 0-10V outputs Microcontroller reduces measurement errors Measurement range 0 to 100% RH ABS Flame retardant housing.
High specification, relative humidity and temperature transmitters for ...
Description:
High specification, relative humidity and temperature transmitters for use with building management systems User configurable for 4-20mA or 0-10V outputs Microcontroller reduces measurement errors Measurement range 0 to 100% RH ABS Flame retardant housing.