Jumo Capillary Thermostat, 300 °C Max, Automatic Reset, 10 A, Surface Mount

Subtotal (1 unit)*

€475.22

(exc. VAT)

€584.52

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +€475.22

*price indicative

RS Stock No.:
279-072
Mfr. Part No.:
603021/20-1-064-50-0-00-30-13-20-200-8-6/000
Manufacturer:
Jumo
Find similar products by selecting one or more attributes.
Select all

Brand

Jumo

Minimum Operating Temperature

50°C

Product Type

Thermostat

Maximum Operating Temperature

300°C

Thermostat Type

Capillary

Contact AC Voltage

230V ac

Contact Current

10A

Series

603021

Standards/Approvals

DIN 3852/2, RoHS, DIN EN 14597, DGRL, EAC

Hazardous Area Certification

No

Mount Type

Surface Mount

Reset Type

Automatic

COO (Country of Origin):
DE
The Jumo 1 Pole Mechanical Surface Mounting Thermostat is very robust and can also be used in rough conditions. The measuring system used operates on the fluid expansion principle and can be used without any problems up to a maximum permissible probe temperature of 345°C. A decisive advantage is that no additional auxiliary energy is necessary for temperature measurement. The electrical connection is made directly to the installed microswitch via screw terminals, which can directly switch a maximum permissible switching capacity of AC 230 V / 10 A. The safety temperature limiter can be used very flexibly and is used in heating, air conditioning and ventilation technology as well as in the plastics industry, in apparatus and mechanical engineering and in furnace construction, in district heating transfer stations and for temperature monitoring in laboratories and climatic chambers.

Shock resistant case with high quality plastic cover

Aluminium die cast lower part

Approved according to DIN EN 14597 and an EAC approval

Protection tube made of high-quality stainless steel

Diameter of 8 mm and fixed with G 1/2 thread according to DIN 3852/2

Max permissible ambient temperature at switch head 80°C and protection class IP54

Desired switch off temperature set with screwdriver after removing case lid

Temperature limiter with high switching point accuracy of +0/-5 K in upper third of scale

If measuring system is damaged and circuit is permanently opened and no contacts are switched