Sifam Tinsley Current Sensor, 5A, 4 20mA output current

  • RS Stock No. 136-5726
  • Mfr. Part No. TT20-V8EF2DRZ00000
  • Manufacturer Sifam Tinsley
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IN
Product Details

Theta 20 Programmable Current Transducers

Sifam Tinsley Theta 20A/20V compact programmable transducers measure and convert AC voltage or current input into a load independent DC output signal. Featuring an LCD display and are on-site configurable.

Features and Benefits

True RMS measurement On-site programmable inputs
On-site selectable output: DC Current or DC Voltage
Output response time < 400 m/sec
Accuracy Class 0.2 (IEC / EN 60688)
Seven segment LCD display
RS485 (ModBus) communication

Sifam Tinsley Current Transducers

Specifications
Attribute Value
Output Current Range 4 20mA
Nominal Current 5A
Supply Voltage 60 300 V ac/dc
Mounting Type DIN Rail
Accuracy 0.2 %
Minimum Operating Temperature 0°C
Maximum Operating Temperature +45°C
Depth 106.5mm
Height 65.5mm
Output Voltage Range 0 10V
Maximum Output Voltage 10V
Width 43.75mm
Minimum Output Voltage 0V
Standards Met EN 60529, EN 61010, EN 61010-1, IEC/EN 60688, UL 94-V0
Temporarily out of stock - back order for despatch 21-07-2020, delivery within 2 working days
Unit of sale: Each
116.59
(exc. VAT)
143.41
(inc. VAT)
units
Per unit
1 - 4
€116.59
5 - 9
€110.75
10 +
€104.92
Related Products
Open loop current transducer Hall effect measuring principle ...
Description:
Open loop current transducer Hall effect measuring principle For measuring DC, AC and pulse currents Galvanic isolation between primary and secondary circuits Housing made from insulating, self-extinguishing material UL94-V0
Measurement of dc currents Large aperture Easy panel ...
Description:
Measurement of dc currents Large aperture Easy panel mounting No insertion losses Supply voltage 20/50Vdc - 22/38Vac Accuracy ±1%Size (Hx WxD) 572 x 30 x 89.7mm Operating Temperature -20 → +50°CWeight 100g.
Measurement of dc currents Large aperture Easy panel ...
Description:
Measurement of dc currents Large aperture Easy panel mounting No insertion losses Supply voltage 20/50Vdc - 22/38Vac Accuracy ±1%Size (Hx WxD) 572 x 30 x 89.7mm Operating Temperature -20 → +50°CWeight 100g.
Split core AC current transducer using proprietary PriME ...
Description:
Split core AC current transducer using proprietary PriME technology Mean sensing RMS measurement. Split core, ideal for retrofitting Extremely low weight Loop powered0-5V, 0-10V, & 4-20mA outputs available Selectable measuring range Selectable voltage output (B10 series only)DIN rail mounting.