Omron Actuator for Use with Interruptor de seguridad D4GS

Subtotal (1 unit)*

€28.73

(exc. VAT)

€35.34

(inc. VAT)

Add to Basket
Select or type quantity
Temporarily out of stock
  • Shipping from 18 November 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +€28.73

*price indicative

RS Stock No.:
746-7220
Mfr. Part No.:
D4GS-NK4
Manufacturer:
Omron
Find similar products by selecting one or more attributes.
Select all

Brand

Omron

Accessory Type

Actuator

Product Type

Actuator

For Use With

Interruptor de seguridad D4GS

Hazardous Area Certification

No

Standards/Approvals

RoHS

Series

D4GS

COO (Country of Origin):
JP

Omron D4GS Series Actuator, For Use With Interruptor de seguridad - D4GS-NK4


This actuator is an accessory designed to operate a safety-door switch in industrial control systems, providing mechanical engagement for door-interlock functions. It is intended for use with Interruptor de seguridad D4GS assemblies and is suitable for incorporation into machine safety circuits where controlled insertion and extraction of an operation key is required.

Features & Benefits


• IP67 main-body protection preserves internal components against dust and water
• Direct-opening contacts ensure positive safety interruption
• 60 N minimum direct-opening force resists accidental actuation
• 100,000 electrical operations at 1A for extended switching life
• Operating range −30 °C to 70 °C for broad environmental tolerance
• Class II double insulation reduces risk of electric shock

Applications


• Suitable for machine-guard interlocks in automated production lines
• Ideal for safeguarding access panels on electrical control cabinets
• used with programmable controllers for safety-input signalling
• Can be used for retrofit D4GS replacement actuator needs in factories
• suitable as an industrial actuator Omron D4GS accessory for safety upgrades

What is the expected mechanical durability under normal ambient conditions?


Mechanical endurance is specified at a minimum of 1,000,000 operations when used within the advised temperature and humidity ranges.

How should the cable be protected to avoid damage?


Secure the cable within 5 cm of the unit and maintain a bending radius greater than 45mm to prevent sheath or conductor stress.

Which contact types are available and how are they used in safety circuits?


Configurations include combinations of NC and NO slow-action contacts

the NC contacts provide direct-opening operation for safety-category circuits, while auxiliary contacts serve PLC inputs or indicators.

Are there restrictions on installation environments?


Do not use where explosive or corrosive gases may be present or where fluids can enter via the key entry, as the key insertion face is not sealed.

What wiring preparation is required for unused conductors?


Cut back the black core insulation and any unused cores to the end of the external sheath before termination to prevent shorting or interference.

Standards

Meets EN (TÜV) standards and CE marking requirements along with a variety of international standard requirements, such as UL and CSA requirements. All NC contacts satisfy requirements for the direct opening mechanism.

Related links

Be the first to know about our latest products and offers

Email address

The personal information you provide to us when signing up to this mailing list will be processed in line with the Privacy Policy