Analog Devices AD9125-M5375-EBZ 16-Bit DAC Evaluation Board for AD9125

  • RS Stock No. 832-9431
  • Mfr. Part No. AD9125-M5375-EBZ
  • Manufacturer Analog Devices
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

Evaluation Board for AD9125 Dual 16-bit DAC

The AD9125 High-Speed DAC Evaluation Boards from Analog Devices, are designed for the assessment of the AD9125 Digital-to-Analogue Converter (DAC). The AD9125 is a dual, 16-bit, high dynamic range TxDAC+ DAC that provides a sample rate of 1000 Msps, permitting a multicarrier generation up to the Nyquist frequency.
The evaluation board for the AD9125 is available in two variations. The AD9125-M5372-EBZ comes with the ADL5372, 1500 MHz to 2500 MHz Quadrature Modulator on board. The AD9125-M5375-EBZ has the ADL5375, 400 MHz to 6 GHz Broadband Quadrature Modulator on-board. To operate the AD9125 evaluation boards, apply power, a clock source, a digital data source, and you are able to observe the DAC output. A low jitter sine or square wave clock is suitable as a source.

Connected with a Data Pattern Generator for rapid evaluation
Software allows control and programming through a USB connection and the SPI port
DUT and clock circuit operating modes are programmed via the SPI port

Kit Contents

AD9125 Evaluation Board
Evaluation Board CD
Mini-USB cable

Digital to Analogue Converters - Analog Devices

Specifications
Attribute Value
Converter Type DAC
Featured Device AD9125
Kit Classification Evaluation Board
Resolution 16-bit
Temporarily out of stock - back order for despatch 19-06-2020, delivery within 2 working days
Unit of sale: Each
551.09
(exc. VAT)
677.84
(inc. VAT)
units
Per unit
1 +
€551.09
Related Products
CN0357 single-supply, low noise, portable gas detector circuit using ...
Description:
CN0357 single-supply, low noise, portable gas detector circuit using an electrochemical sensor The Alphasense CO-AX carbon monoxide sensor is used in this example. Electrochemical sensors offer several advantages for instruments that detect or measure the concentration of many toxic gases. Most ...
This circuit uses three precision current to voltage ...
Description:
This circuit uses three precision current to voltage conversion stages that drive a single-supply, low power, low noise, 16-bit, Σ-Δ analog-to-digital converter (ADC) with three differential inputsThe circuit deviates from the traditional approach by eliminating all mechanical and optical components, ...
The Evaluation Board for AD5933 Z-converter / Analyser ...
Description:
The Evaluation Board for AD5933 Z-converter / Analyser is a full featured evaluation board that can be used in various applications such as electrochemical analysis, impedance spectroscopy, complex impedance measurement, corrosion monitoring and protection equipment, biomedical and automotive sensors and ...
This evaluation board is a completely isolated 12-bit, ...
Description:
This evaluation board is a completely isolated 12-bit, 300kSPS data acquisition system utilizing only three active devices The system processes 4mA to 20mA input signals using a single 3.3V supply. The total error after room temperature calibration is +/-0.06% FSR ...