Schneider Electric Multi9 C60SP Miniature Circuit Breaker, 3-Pole, 32 A, Type B, 440 V AC, 14 kA Breaking Capacity
- RS Stock No.:
- 211-2345
- Mfr. Part No.:
- M9F21332
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
€89.98
(exc. VAT)
€110.68
(inc. VAT)
Stock information currently inaccessible
Units | Per unit |
|---|---|
| 1 + | €89.98 |
*price indicative
- RS Stock No.:
- 211-2345
- Mfr. Part No.:
- M9F21332
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 3 | |
| Current Rating | 32 A | |
| Tripping Characteristics | Type B | |
| Rated AC Voltage | 440 V | |
| Mount Type | Clip-on | |
| Breaking Capacity | 14kA | |
| Range | Multi9 | |
| Series | C60SP | |
| Terminal Type | Tunnel Type Terminal | |
| IP Rating | IP20, IP40 | |
| Depth | 72mm | |
| Height | 81mm | |
| Width | 54 mm | |
| Standards/Approvals | CSA C22.2 No 235, EN/IEC 60947-2, GB 14048.2, UL 1077 | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Thermal Magnetic | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 3 | ||
Current Rating 32 A | ||
Tripping Characteristics Type B | ||
Rated AC Voltage 440 V | ||
Mount Type Clip-on | ||
Breaking Capacity 14kA | ||
Range Multi9 | ||
Series C60SP | ||
Terminal Type Tunnel Type Terminal | ||
IP Rating IP20, IP40 | ||
Depth 72mm | ||
Height 81mm | ||
Width 54 mm | ||
Standards/Approvals CSA C22.2 No 235, EN/IEC 60947-2, GB 14048.2, UL 1077 | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Thermal Magnetic | ||
- COO (Country of Origin):
- FR
The Schneider Electric's C60SP Series are multi-standard miniature circuit breakers and supplementary protection as defined by UL 1077. It has function such as tripping and electrical fault indication by the addition of auxiliaries.
Circuit protection against short-circuit currents
Circuit protection against overload currents
Related links
- Schneider Electric Multi 9 C60SP MCB 32A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 32A Curve C 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 32A Curve D 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 2A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 50A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 20A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 6A Curve B 15 kA Breaking Capacity
- Schneider Electric Multi 9 C60SP MCB 40A Curve B 15 kA Breaking Capacity