Siemens SENTRON Series Residual Current Circuit Breaker, 40 A, 4-Pole, 300 mA, Type A, 10 kA 400 V ac
- RS Stock No.:
- 211-9697
- Distrelec Article No.:
- 301-37-613
- Mfr. Part No.:
- 5SV3644-6KK01
- Manufacturer:
- Siemens
Subtotal (1 unit)*
€330.22
(exc. VAT)
€406.17
(inc. VAT)
Temporarily out of stock
- Shipping from 30 March 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | €330.22 |
*price indicative
- RS Stock No.:
- 211-9697
- Distrelec Article No.:
- 301-37-613
- Mfr. Part No.:
- 5SV3644-6KK01
- Manufacturer:
- Siemens
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 40 A | |
| Number of Poles | 4 | |
| Range | SENTRON | |
| Series | SENTRON | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type A | |
| Mount Type | DIN Rail | |
| Terminal Type | Screw | |
| Standards/Approvals | CE, UKCA, EAC, VDE | |
| Depth | 70mm | |
| Height | 90mm | |
| Width | 72 mm | |
| Breaking Capacity | 10kA | |
| Tripping Mechanism | Electromagnetic | |
| Rated AC Voltage | 400 V ac | |
| Earth Leakage Protection Type | Type A | |
| Break Time | Short | |
| Reset Actuator Type | Toggle Switch | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 40 A | ||
Number of Poles 4 | ||
Range SENTRON | ||
Series SENTRON | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type A | ||
Mount Type DIN Rail | ||
Terminal Type Screw | ||
Standards/Approvals CE, UKCA, EAC, VDE | ||
Depth 70mm | ||
Height 90mm | ||
Width 72 mm | ||
Breaking Capacity 10kA | ||
Tripping Mechanism Electromagnetic | ||
Rated AC Voltage 400 V ac | ||
Earth Leakage Protection Type Type A | ||
Break Time Short | ||
Reset Actuator Type Toggle Switch | ||
- COO (Country of Origin):
- DE
The Siemens Residual current operated circuit breaker has 4-pole and type A. Used for short-time delayed. Operating current is 40 A and trippening residual current 300 mA. Supply voltage is 400 V. RCD is the residual current device for touch protection RCCBs, type A trip with both sinusoidal alternating currents (type AC) and pulsating DC residual currents. They are used mainly with single-phase consumers with electrical components in the supply unit, e.g. in residential and functional structures. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
Protection class IP IP20 if the distribution board is installed, with connected conductors
Silicon- free