Aoip Instrumentation CP-6632 Current & Voltage Calibrator, Max Voltage 50V 25 mA
- RS Stock No.:
- 791-5451
- Mfr. Part No.:
- CP6632
- Manufacturer:
- Aoip Instrumentation
Subtotal (1 unit)*
€901.20
(exc. VAT)
€1,108.48
(inc. VAT)
In Stock
- 7 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | €901.20 |
*price indicative
- RS Stock No.:
- 791-5451
- Mfr. Part No.:
- CP6632
- Manufacturer:
- Aoip Instrumentation
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Aoip Instrumentation | |
| Maximum Voltage Measurement | 50V | |
| Product Type | Current & Voltage Calibrator | |
| Maximum Current Measurement | 25mA | |
| Accuracy | ±0.015 % | |
| Standards/Approvals | No | |
| Power Source | Battery | |
| Battery Type | AA | |
| Weight | 306g | |
| Height | 45mm | |
| Length | 157mm | |
| Hazardous Area Certification | No | |
| Maximum Operating Temperature | 50°C | |
| Maximum Source Current | 25mA | |
| Maximum Source Voltage | 15V | |
| Safety Category Level | CAT II | |
| Safety Category Voltage | 60V | |
| Model Number | CP-6632 | |
| Calibrated | UKAS | |
| Minimum Operating Temperature | -10°C | |
| Width | 85 mm | |
| Minimum Source Voltage | 0V | |
| Minimum Source Current | 0mA | |
| Select all | ||
|---|---|---|
Brand Aoip Instrumentation | ||
Maximum Voltage Measurement 50V | ||
Product Type Current & Voltage Calibrator | ||
Maximum Current Measurement 25mA | ||
Accuracy ±0.015 % | ||
Standards/Approvals No | ||
Power Source Battery | ||
Battery Type AA | ||
Weight 306g | ||
Height 45mm | ||
Length 157mm | ||
Hazardous Area Certification No | ||
Maximum Operating Temperature 50°C | ||
Maximum Source Current 25mA | ||
Maximum Source Voltage 15V | ||
Safety Category Level CAT II | ||
Safety Category Voltage 60V | ||
Model Number CP-6632 | ||
Calibrated UKAS | ||
Minimum Operating Temperature -10°C | ||
Width 85 mm | ||
Minimum Source Voltage 0V | ||
Minimum Source Current 0mA | ||
RoHS Status: Exempt
- COO (Country of Origin):
- FR
Aoip Instrumentation Current and Voltage Calibrator
The Aoip Instrumentation current and voltage calibrator is an accurate handheld instrument for process signals (150 ppm reading accuracy). This device measures or generates process current and voltage. It has a current measurement from 0mA to 25mA with 24V loop power supply and voltage from 0V to 50V. The calibrator is robust and easy-to-use. This tool has been designed to make maintenance operations easier on sensors and transmitters using process signals such as 4-20mA or 0-10V. The instrument is adapted to the various process installations due to scaling function and specific ranges. It is responsible for simulating ramps, steps, and fixed values to control process transmitters, panel meters and recorders.
Features and Benefits
Voltage/ current calibrator for process loops.
Current simulations from 0mA to 25mA with 24V loop power supply and voltage from 0V to 15V
High accuracy 0.015% reading with an adjustable resolution of 1mV and 1μA
Values displayed in A, mV and, %
Low temperature coefficient: 15ppm/°C in voltage and 20ppm/°C in current
Active or passive loop power supply
Measurements with HOLD function
Simulation of ramps, pre-programmed steps and synthesiser values
Display of minimum, maximum and average value
Delivered with 4 alkaline AA batteries in standard
Backlight enabled
Continuity test
Compatible with HART transmitters
Impact proof sheathing
USB socket for downloading
Supplied with measurement cables
Applications
Electrical servicing and maintenance
Laboratories
Electronic servicing and maintenance
Industrial automation
Certifications
IP45 rated
EN 61010-1
EN 61000-4-2
EN 61000-4-3
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
EN 61000-3-2
EN 61000-3-3
EN 55022, class B
CP6632 voltage / current calibrator
Voltage / current calibrator for process loops.
Current simulations from 0 → 25 mA with 24 V loop power supply and voltage from 0 → 15 V.
Current measurement from 0 → 25 mA with 24 V loop power supply and voltage from 0 → 50 V.
Continuity test.
Compatible with HART transmitters.
Calibration of transmitters, on-site measurements, integrated valve test.
Scaling in units and in % for easy reading of data with double display for 4 → 20 mA and 0 → 10 V process signals.
Emission of ramps and increments to test the linearity and the range of transmitters, with retarder function.
Graphic display on screen with date and time, backlit with adjustable contrast. Selectable display resolution of up to 0.001 mA or 0.001 V.
Display of measurement statistics: Min, Max and Average.
Impact proof sheathing.
USB socket for downloading.
Supplied with measurement cables.
Note
Powered by 4 AA batteries or by using battery charger kit (this has EU not UK plug) available separately: AN6011 5083757
Related links
- Aoip Instrumentation CP-6632 Current & Voltage Calibrator Max Current 25mA, RS Calibration
- Aoip Instrumentation CP-6632 Current & Voltage Calibrator Max Current 25mA
- Fluke 715 Current & Voltage Calibrator Max Current 24mA, UKAS Calibration
- Time Electronics 1044 Current & Voltage Calibrator Max Current 20mA, UKAS Calibration
- Chauvin Arnoux CA 1631 Current & Voltage Calibrator Max Current 24mA, UKAS Calibration
- RS PRO 133 Current & Voltage Calibrator Max Current 24mA, UKAS Calibration
- Time Electronics 1030 Current & Voltage Calibrator Max Current 100mA, UKAS Calibration
- Time Electronics 1024 Current & Voltage Calibrator UKAS Calibration
