Fluke 1587 FC Insulation Multimeter, 50 V Min, 1000 V Max, 2 GΩ CAT IV, CAT III, UKAS
- RS Stock No.:
- 905-7011
- Mfr. Part No.:
- FLUKE-1587 FC
- Manufacturer:
- Fluke
Subtotal (1 unit)*
€1,314.00
(exc. VAT)
€1,616.22
(inc. VAT)
Limited stock
- 162 left, ready to ship
- Plus 33 left, shipping from 01 October 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | €1,314.00 |
*price indicative
- RS Stock No.:
- 905-7011
- Mfr. Part No.:
- FLUKE-1587 FC
- Manufacturer:
- Fluke
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Insulation Tester | |
| Model Number | 1587 FC | |
| Tester Type | Insulation Multimeter | |
| Maximum Test Voltage | 1000V | |
| Minimum Test Voltage | 50V | |
| Display Type | LCD Backlight | |
| Test Current | 1mA | |
| Battery Type | AA, NEDA 15A | |
| Power Source | Battery | |
| Battery Life | 1000h | |
| Minimum Operating Temperature | -20°C | |
| Insulation Testing Resistance | 2GΩ | |
| Safety Category Voltage | 600, 1000V | |
| Maximum Operating Temperature | +50°C | |
| Safety Category Level | CAT IV, CAT III | |
| Width | 100mm | |
| Length | 203mm | |
| Standards/Approvals | CE, CSA | |
| Height | 50mm | |
| Weight | 550g | |
| Calibrated | UKAS | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Insulation Tester | ||
Model Number 1587 FC | ||
Tester Type Insulation Multimeter | ||
Maximum Test Voltage 1000V | ||
Minimum Test Voltage 50V | ||
Display Type LCD Backlight | ||
Test Current 1mA | ||
Battery Type AA, NEDA 15A | ||
Power Source Battery | ||
Battery Life 1000h | ||
Minimum Operating Temperature -20°C | ||
Insulation Testing Resistance 2GΩ | ||
Safety Category Voltage 600, 1000V | ||
Maximum Operating Temperature +50°C | ||
Safety Category Level CAT IV, CAT III | ||
Width 100mm | ||
Length 203mm | ||
Standards/Approvals CE, CSA | ||
Height 50mm | ||
Weight 550g | ||
Calibrated UKAS | ||
RoHS Status: Exempt
- COO (Country of Origin):
- US
Fluke Insulation Tester, 1000V Maximum Test Voltage, 2GΩ Insulation Testing Resistance - FLUKE-1587 FC
This insulation tester is a battery-powered handheld instrument designed for insulation resistance measurement and general electrical diagnostics in industrial environments. It combines a digital multimeter capability with insulation testing up to high voltages, providing a single tool for troubleshooting and preventative maintenance across installations that require robust safety ratings and temperature tolerance.
Features and Benefits:
• 1000V output for high-voltage insulation verification
• 1mA short-circuit test current for controlled discharge protection
• 2GΩ maximum insulation range for detecting high-resistance faults
• CAT IV 600V and CAT III 1000V safety categorisation for onsite use
• AA battery operation with 1000h meter life for extended field work
• LCD backlight display for readable measurements in low light
• 1mA short-circuit test current for controlled discharge protection
• 2GΩ maximum insulation range for detecting high-resistance faults
• CAT IV 600V and CAT III 1000V safety categorisation for onsite use
• AA battery operation with 1000h meter life for extended field work
• LCD backlight display for readable measurements in low light
Applications
• Suitable for motor winding insulation condition checks
• Ideal for commissioning cables and switchgear insulation
• Used for preventative maintenance on industrial assets
• Can be used for field verification of high-voltage systems
• Used with temperature compensation workflows for baseline tracking
• Ideal for commissioning cables and switchgear insulation
• Used for preventative maintenance on industrial assets
• Can be used for field verification of high-voltage systems
• Used with temperature compensation workflows for baseline tracking
What insulation test voltages are available?
The instrument provides selectable test voltages including 50V, 100V, 250V, 500V and 1000V depending on the model.
How does the tester behave when measuring live circuits?
The tester inhibits insulation tests if a Terminal voltage greater than 30V is detected to prevent unsafe testing.
What environmental conditions can it operate in?
It operates between -20°C and 55°C and withstands non-condensing humidity up to specified ranges across temperature bands.
How is capacitive discharge handled after testing?
The unit auto-discharges capacitive voltage, achieving discharge times below 0.5s for capacitances of 1μF or less.
What protection exists for current inputs?
The mA input is protected by a 0.44A, 1000V fuse with an IR rating of 10kA to limit fault current.
Supplied with
The Fluke 1587 FC Insulation Multimeter comes with a remote probe, test leads, alligator clips, K-type thermocouple, hard case and user documentation.
Related links
- Fluke 1587 FC Insulation Multimeter 1000 V Max CAT III, RSCAL
- Fluke 1587 FC Insulation Multimeter 1000 V Max CAT III
- Fluke 1587 Insulation Tester 1000 V Max CAT IV UKAS
- Fluke 1587 Current Clamp Fc Multimeter Kit, UKAS
- Fluke 1587 Advanced Motor and Drive Troubleshooting Multimeter Kit, UKAS
- Fluke 1587FC/TPAK/C25 Insulation Multimeter 1000 V Max CAT IV 600 V
- Fluke 1587FC/TPAK/C25 Insulation Multimeter 1000 V Max CAT IV 600 V, UKAS
- Fluke 1577 Insulation Multimeter 1000 V Max CAT IV, UKAS
