ABB System Pro M Compact S200 Miniature Circuit Breaker, 2-Pole, 15A, Type K, 400V ac AC, 6 kA Breaking Capacity
- RS Stock No.:
- 237-3232
- Mfr. Part No.:
- 2CDS252001R0457
- Manufacturer:
- ABB
Subtotal (1 unit)*
€87.11
(exc. VAT)
€107.15
(inc. VAT)
Stocked by manufacturer
- Ready to ship from 18 June 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | €87.11 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 237-3232
- Mfr. Part No.:
- 2CDS252001R0457
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Miniature Circuit Breaker | |
| Number of Poles | 2 | |
| Current Rating | 15A | |
| Tripping Characteristics | Type K | |
| Rated AC Voltage | 400V ac | |
| Breaking Capacity | 6kA | |
| Mount Type | DIN Rail | |
| Range | System Pro M Compact | |
| Series | S200 | |
| Terminal Type | Screw | |
| IP Rating | IP20, IP40 | |
| Width | 35mm | |
| Standards/Approvals | IEC/EN 60947-2, IEC/EN 60898-1 | |
| Height | 88mm | |
| Depth | 69mm | |
| Better World Claim | Designed for Disassembly | |
| Better World Product | Yes | |
| Tripping Mechanism | Thermomagnetic, Electromagnetic | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Miniature Circuit Breaker | ||
Number of Poles 2 | ||
Current Rating 15A | ||
Tripping Characteristics Type K | ||
Rated AC Voltage 400V ac | ||
Breaking Capacity 6kA | ||
Mount Type DIN Rail | ||
Range System Pro M Compact | ||
Series S200 | ||
Terminal Type Screw | ||
IP Rating IP20, IP40 | ||
Width 35mm | ||
Standards/Approvals IEC/EN 60947-2, IEC/EN 60898-1 | ||
Height 88mm | ||
Depth 69mm | ||
Better World Claim Designed for Disassembly | ||
Better World Product Yes | ||
Tripping Mechanism Thermomagnetic, Electromagnetic | ||
- COO (Country of Origin):
- DE
ABB S200 Series Miniature Circuit Breaker, 15A Current, 400V Rated AC Voltage - 2CDS252001R0457
This miniature circuit-breaker is a Compact two-pole protective device designed to interrupt overcurrents in low-voltage AC and DC systems. It combines a delayed thermal element for overload protection with an electromagnetic trip for short-circuit interruption, and is intended for DIN-rail installation in residential, commercial and industrial electrical panels.
Features & Benefits
• 15A rated current providing consistent circuit protection
• Type K characteristic for applications with moderate inrush currents
• 6 kA breaking capacity limiting fault energy effectively
• Thermomagnetic electromagnetic tripping for dual-mode protection
• Screw terminals enabling secure conductor connection
• 35mm product width saving panel space
• Type K characteristic for applications with moderate inrush currents
• 6 kA breaking capacity limiting fault energy effectively
• Thermomagnetic electromagnetic tripping for dual-mode protection
• Screw terminals enabling secure conductor connection
• 35mm product width saving panel space
Applications
• Suitable for motor control circuits with moderate starting currents
• Ideal for commercial distribution boards on DIN rail
• Used for protection of lighting and general-purpose feeders
• Suitable for industrial control panels requiring selective trips
• Ideal for commercial distribution boards on DIN rail
• Used for protection of lighting and general-purpose feeders
• Suitable for industrial control panels requiring selective trips
What voltages can it be used with in AC systems?
It is rated for operational AC voltages up to 400V and can be applied within that range on low-voltage installations.
How is the device mounted and secured in an enclosure?
It clips onto standard TH35 DIN rails and is compatible with both 35x15mm and 35x7.5mm rails as specified.
What environmental conditions can it withstand during operation?
It operates across an ambient temperature range from −25 °C to +55 °C and is designed for pollution degree 3 environments.
Can auxiliary accessories be added for remote signalling or tripping?
Yes, a range of auxiliary contacts, shunt trips and undervoltage releases are available to extend functionality.
How does the unit indicate contact position?
It provides a Visual red/green indication to show on/off contact status.
Related links
- ABB System Pro M Compact S200 Miniature Circuit Breaker 15A 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker 80A 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker 63A 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker 10A 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker 16A 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 M UC Miniature Circuit Breaker 15A 400V ac AC 10 kA
- ABB System Pro M Compact S200 Miniature Circuit Breaker 20A 400V ac AC, 6 kA Breaking Capacity
- ABB System Pro M Compact S200 Miniature Circuit Breaker 32A 400V ac AC, 6 kA Breaking Capacity