Fluke 116 Handheld Digital Multimeter True RMS, 600 μA ac, 600 μA dc, 600 V ac
- RS Stock No.:
- 616-1476
- Distrelec Article No.:
- 176-05-439
- Mfr. Part No.:
- FLUKE-116 EUR
- Manufacturer:
- Fluke
Subtotal (1 unit)*
€344.00
(exc. VAT)
€423.12
(inc. VAT)
- Plus 2 left, shipping from 13 April 2026
- Plus 8 left, shipping from 13 April 2026
- Plus 1 left, shipping from 14 April 2026
Units | Per unit |
|---|---|
| 1 + | €344.00 |
*price indicative
Calibration Options:
- Calibration Type:
- UKAS
- RS Stock No.
- 625-0576
Each
€436.00
(exc. VAT)
€536.28
(inc. VAT)
- RS Stock No.:
- 616-1476
- Distrelec Article No.:
- 176-05-439
- Mfr. Part No.:
- FLUKE-116 EUR
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Multimeter Type | Handheld | |
| Product Type | Multimeter | |
| Resistance Resolution | 100mΩ | |
| Display Type | Digital | |
| Model Number | 116 | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum DC Current Measurement | 600μA dc | |
| Maximum AC Current Measurement | 600μA ac | |
| Maximum Resistance Measurement | 40mΩ | |
| True RMS | Yes | |
| DC Current Accuracy | ±1 % rdg + 2 Digits | |
| AC Voltage Accuracy | ±1 % rdg + 3 Digits | |
| DC Voltage Accuracy | ±0.5 % rdg + 2 Digits | |
| AC Current Accuracy | ±1.5 % rdg + 3 Digits | |
| AC Current Resolution | 0.1μA ac | |
| DC Current Resolution | 0.1μA dc | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| Maximum Frequency | 1kHz | |
| Minimum Operating Temperature | -10°C | |
| Resistance Measurement Accuracy | ±1.5 % rdg + 2 Digits | |
| Battery Life | 400h | |
| Maximum Operating Temperature | 50°C | |
| Length | 46mm | |
| Weight | 550g | |
| Standards/Approvals | No | |
| Width | 84mm | |
| Height | 167mm | |
| Safety Category Level | CAT III | |
| Safety Category Voltage | 600V | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Multimeter Type Handheld | ||
Product Type Multimeter | ||
Resistance Resolution 100mΩ | ||
Display Type Digital | ||
Model Number 116 | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance, Temperature | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum DC Current Measurement 600μA dc | ||
Maximum AC Current Measurement 600μA ac | ||
Maximum Resistance Measurement 40mΩ | ||
True RMS Yes | ||
DC Current Accuracy ±1 % rdg + 2 Digits | ||
AC Voltage Accuracy ±1 % rdg + 3 Digits | ||
DC Voltage Accuracy ±0.5 % rdg + 2 Digits | ||
AC Current Accuracy ±1.5 % rdg + 3 Digits | ||
AC Current Resolution 0.1μA ac | ||
DC Current Resolution 0.1μA dc | ||
AC Voltage Resolution 0.1mV ac | ||
DC Voltage Resolution 0.1 mV dc | ||
Maximum Frequency 1kHz | ||
Minimum Operating Temperature -10°C | ||
Resistance Measurement Accuracy ±1.5 % rdg + 2 Digits | ||
Battery Life 400h | ||
Maximum Operating Temperature 50°C | ||
Length 46mm | ||
Weight 550g | ||
Standards/Approvals No | ||
Width 84mm | ||
Height 167mm | ||
Safety Category Level CAT III | ||
Safety Category Voltage 600V | ||
RoHS Status: Exempt
Fluke Multimeter, 600V Maximum DC Voltage Measurement, True RMS Functionality - FLUKE-116 EUR
Features & Benefits
• 600V and 600A ranges support high-voltage and high-current tasks
• Microamp input checks flame sensors and low-current circuits
• 1kHz frequency range captures up to 50kHz on voltage inputs
• LoZ mode prevents false readings from ghost voltages
• 400h battery life enables extended field operation without frequent replacement
Applications
• Ideal for electricians verifying AC and DC supply integrity
• Used for testing flame-sensor circuits and microamp signals
• Can be used with temperature probes for refrigeration maintenance
• Used for capacitance and frequency checks in control panels
What battery type does it use and how long will it operate typically?
How does the instrument perform under poor lighting conditions?
What protection and safety features are incorporated for field use?
Which measurements include capacitance and what ranges are available?
How does the meter capture transient signal behaviour?
Standards
Contents
Related links
- Fluke 116 Handheld Digital Multimeter True RMS 600 μA dc, 600 V ac - RSCAL Calibrated
- Fluke 116 Handheld Digital Multimeter True RMS 600 μA dc, 600 V ac - UKAS Calibrated
- Fluke 117 Fluke 117 Handheld Digital Multimeter True RMS 10 A dc, 600 V ac
- Fluke 117 Fluke 117 Handheld Digital Multimeter True RMS 10 A dc, 600 V ac - RSCAL Calibrated
- Fluke 117 Fluke 117 Handheld Digital Multimeter True RMS 10 A dc, 600 V ac - UKAS Calibrated
- Fluke 113 Fluke 113 Handheld Digital Multimeter True RMS, 600 V ac
- Fluke 287 Handheld Digital Multimeter True RMS
- Fluke 289 Handheld Digital Multimeter True RMS