Fluke 117 Fluke 117 Digital Digital Multimeter True RMS, 10 A ac, 10 A dc, 600 V ac, UKAS Calibrated
- RS Stock No.:
- 625-0605
- Mfr. Part No.:
- FLUKE 117 EUR
- Manufacturer:
- Fluke
Subtotal (1 unit)*
€451.00
(exc. VAT)
€554.73
(inc. VAT)
- 95 unit(s) ready to ship
Units | Per unit |
|---|---|
| 1 + | €451.00 |
*price indicative
- RS Stock No.:
- 625-0605
- Mfr. Part No.:
- FLUKE 117 EUR
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Multimeter | |
| Multimeter Type | Digital | |
| Display Type | Digital | |
| Resistance Resolution | 100mΩ | |
| Model Number | 117 | |
| Functions Measured | AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum Resistance Measurement | 40mΩ | |
| Maximum DC Current Measurement | 10A dc | |
| Maximum AC Current Measurement | 10A ac | |
| True RMS | Yes | |
| AC Current Accuracy | ±1.5 % rdg + 3 Digits | |
| DC Current Accuracy | ±1 % rdg + 3 Digits | |
| AC Voltage Accuracy | ±1 % rdg + 3 Digits | |
| DC Voltage Accuracy | ±0.5 % rdg + 2 Digits | |
| AC Current Resolution | 0.001A ac | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| DC Current Resolution | 0.001A ac | |
| Maximum Frequency | 50kHz | |
| Power Source | Battery | |
| Resistance Measurement Accuracy | ±1.5 % rdg + 2 Digits | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 400h | |
| Width | 84mm | |
| Standards/Approvals | CE, N10140, TUV, CSAus, UL, VDE | |
| Series | Fluke 117 | |
| Length | 167mm | |
| Height | 46mm | |
| Weight | 550g | |
| Safety Category Level | CAT III | |
| Safety Category Voltage | 600V | |
| Battery Type | Alkaline | |
| Calibrated | UKAS | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Multimeter | ||
Multimeter Type Digital | ||
Display Type Digital | ||
Resistance Resolution 100mΩ | ||
Model Number 117 | ||
Functions Measured AC Current, AC Voltage, Capacitance, Continuity, DC Current, DC Voltage, Diode Test, Frequency, Resistance | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum Resistance Measurement 40mΩ | ||
Maximum DC Current Measurement 10A dc | ||
Maximum AC Current Measurement 10A ac | ||
True RMS Yes | ||
AC Current Accuracy ±1.5 % rdg + 3 Digits | ||
DC Current Accuracy ±1 % rdg + 3 Digits | ||
AC Voltage Accuracy ±1 % rdg + 3 Digits | ||
DC Voltage Accuracy ±0.5 % rdg + 2 Digits | ||
AC Current Resolution 0.001A ac | ||
AC Voltage Resolution 0.1mV ac | ||
DC Voltage Resolution 0.1 mV dc | ||
DC Current Resolution 0.001A ac | ||
Maximum Frequency 50kHz | ||
Power Source Battery | ||
Resistance Measurement Accuracy ±1.5 % rdg + 2 Digits | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Battery Life 400h | ||
Width 84mm | ||
Standards/Approvals CE, N10140, TUV, CSAus, UL, VDE | ||
Series Fluke 117 | ||
Length 167mm | ||
Height 46mm | ||
Weight 550g | ||
Safety Category Level CAT III | ||
Safety Category Voltage 600V | ||
Battery Type Alkaline | ||
Calibrated UKAS | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
Fluke Multimeter, 600V Maximum DC Voltage, 20A Maximum AC Current - FLUKE 117 EUR
Features & Benefits
• Measures up to 600V and 20A for broad system coverage
• Frequency response to 50kHz for high‑frequency diagnostics
• Low‑resistance measurement down to 40mΩ for tight contact checks
• Diode and continuity tests detect opens and shorts quickly
• Battery life approximately 400 h for prolonged field operation
**Applications**
• Ideal for commissioning AC and DC power systems
• Used for capacitor testing and circuit tuning in electronics
• Can be used for motor drive frequency verification up to 50kHz
• Suitable for testing clamp‑free current scenarios up to 20A
What protection ratings and approvals does it have for industrial use?
How does the meter handle inrush or short‑duration current measurements?
What display and measurement update behaviour should I expect?
Which battery type is required and what are operating environment limits?
Can it measure capacitance and temperature?
Note
Contents
Related links
- Fluke 117 Fluke 117 Handheld Digital Multimeter True RMS 10 A dc, 600 V ac - RSCAL Calibrated
- Fluke 117 Fluke 117 Handheld Digital Multimeter True RMS 10 A dc, 600 V ac
- Fluke 87V 87V Handheld Digital Multimeter True RMS 10 A, 1000 V - UKAS Calibrated
- Fluke 113 Fluke 113 Handheld Digital Multimeter True RMS, 600 V ac - UKAS Calibrated
- Fluke 116 Handheld Digital Multimeter True RMS 600 μA dc, 600 V ac - UKAS Calibrated
- Fluke 87V 87V Handheld Digital Multimeter True RMS 10 A, 1000 V - RSCAL Calibrated
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1 kV ac - UKAS Calibrated
- Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS 400 mA dc, 1 kV ac - UKAS Calibrated