Honeywell Technologies HSCDRRN010MDAA3 Pressure SensorBoard 8 DIP

Bulk discount available
View bulk pricing options

Subtotal (1 unit)*

€81.20

(exc. VAT)

€99.88

(inc. VAT)

Add to Basket
Select or type quantity
In Stock
  • 58 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.

Units
Per unit
1 - 4€81.20
5 - 9€72.02
10 - 24€67.56
25 - 39€64.72
40 +€63.83

*price indicative

Packaging Options:
RS Stock No.:
211-9923
Mfr. Part No.:
HSCDRRN010MDAA3
Manufacturer:
Honeywell
Find similar products by selecting one or more attributes.
Select all

Brand

Honeywell

Product Type

Pressure Sensor

Maximum Overload Pressure

75kPa

Sensor Type

Piezoresistive Pressure Sensor

Mount Type

Board

Package Type

DIP

Pin Count

8

Minimum Supply Voltage

3.3V

Maximum Operating Pressure

1 kPa

Accuracy

±0.25 %

Maximum Supply Voltage

5V

Port Type

Dual Radial Barbed

Maximum Operating Temperature

+85°C

Width

13.3mm

Standards/Approvals

ISO 9001

Length

10mm

Height

13.75mm

Series

HSC

Minimum Operating Pressure

-10mbar

Automotive Standard

ISO 9001

Minimum Operating Temperature

-20°C

Honeywell HSC Series Differential Pressure Sensor, ±0.25% Accuracy, 3.3V Minimum Supply Voltage - HSCDRRN010MDAA3


This differential pressure sensor measures pressure difference between two ports and provides a ratiometric analogue or 14‑bit digital output for use with low‑voltage systems. It is intended for non‑corrosive, non‑ionic gases and is calibrated and temperature‑compensated for accurate readings across its compensated temperature range. The device is board‑mountable and available with dual radial barbed ports in a DIP package for straightforward PCB integration.

Features and Benefits:


• ±0.25%FSS accuracy reduces software correction needs
• Operates from 3.3V to 5V for low‑voltage designs
• Calibrated and compensated for temperature stability
• Fast update rate supporting up to 2kHz digital output
• High overload protection up to 75kPa improves robustness
• Operates from -20°C to 85°C for industrial conditions

Applications


• Used for ventilator and respiratory flow monitoring
• Suitable for HVAC filter clog detection systems
• Ideal for gas flow instrumentation and calibration rigs
• Used with oxygen concentrators and anaesthesia machines
• Can be used for barometry and indoor Air quality monitoring

What media may be applied to the ports?


The sensor is for non‑corrosive, non‑ionic gases, liquid‑media options exist for Port1 only on selected ranges and require compatible, particulate‑free fluids.

How is the sensor protected during solder assembly?


It meets IPC/JEDEC J‑STD‑020E moisture sensitivity level 1 allowing standard reflow without lengthy pre‑bake when handled per floor‑life guidance.

What digital interfaces are available and what resolution do they provide?


Digital outputs include I²C or SPI‑compatible formats with a minimum 12‑bit sensor resolution and up to 14‑bit digital output.

How does the device behave after power‑up?


Start‑up time to data‑ready is typically 3 MS for digital versions and up to 5 MS for analogue versions.

What mechanical mounting and port arrangements are offered?


The board‑mount package supports DIP pin mounting and variants include dual radial barbed port options for simple tubing connection.