Schneider Electric Residual Current Circuit Breaker with Overload Protection, 10A Current Rating, 1-Pole, 30 mA Trip
- RS Stock No.:
- 654-680
- Mfr. Part No.:
- A9D56610
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
€140.99
(exc. VAT)
€173.42
(inc. VAT)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | €140.99 |
*price indicative
- RS Stock No.:
- 654-680
- Mfr. Part No.:
- A9D56610
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Current Rating | 10A | |
| Product Type | Residual Current Circuit Breaker with Overload Protection | |
| Series | A9d | |
| Range | Acti9 | |
| Number of Poles | 1 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Terminal Type | Screw Clamp | |
| Depth | 72mm | |
| Width | 18mm | |
| Height | 110mm | |
| Breaking Capacity | 10000A | |
| Standards/Approvals | BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | |
| Application | Distribution | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Current Rating 10A | ||
Product Type Residual Current Circuit Breaker with Overload Protection | ||
Series A9d | ||
Range Acti9 | ||
Number of Poles 1 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Terminal Type Screw Clamp | ||
Depth 72mm | ||
Width 18mm | ||
Height 110mm | ||
Breaking Capacity 10000A | ||
Standards/Approvals BS EN 61009-1, IEC 61009-1, IEC 61009-2-2 | ||
Application Distribution | ||
- COO (Country of Origin):
- ES
The Schneider Electric Residual current circuit breaker with overcurrent protection (RCD/MCB) Acti 9 iDPN N Vigi, 6kA (IEC/EN 61009-2-1). 1-pole plus N, rated current 10A, characteristic B, earth fault sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 230V AC, insulation voltage (Ui) 400V AC. Ensures comprehensive protection of final circuits against overcurrent's and fault currents. Switches and disconnects circuits. Snap action for low-wear switching of the contacts. Mechanically isolated red indicator in case of fault tripping of the miniature circuit breaker or tripping due to a fault current. Clear switch position indication via green marking on the device's switch knob. Test button for regular function testing. Trip unit technology: thermomagnetic.
Control type is toggle switch
Local signaling is ON, OFF, fault trip
Assembly mode is attachable
Mounting bracket is DIN rail
Related links
- Schneider Electric Residual Current Circuit Breaker with Overload Protection 1-Pole, 30 mA Trip
- Contactum Residual Current Circuit Breaker with Overload Protection 1-Pole
- Lovato Residual Current Circuit Breaker with Overload Protection 1-Pole
- Hager Residual Current Circuit Breaker with Overload Protection 1-Pole
- Siemens Residual Current Circuit Breaker with Overload Protection 1-Pole
- ABB Residual Current Circuit Breaker with Overload Protection 1-Pole Type
- Legrand Residual Current Circuit Breaker with Overload Protection 1-Pole
- Eaton Residual Current Circuit Breaker with Overload Protection 1-Pole