Unitronic® LiYCY cable
From Lapp, the Unitronic LiYCY series of data cables are DIN colour coded, and ideal for low frequency applications. These data or signal cables are used for computers and electronic control devices, and are screened to minimize electrical interference. The cable also features small dimensions and outer diameter, which makes it suitable for fixed installations where space saving is a concern.
The Unitronic LiYCY cable is flame retardant and suitable for use in dry or damp rooms.
Features and Benefits
Core insulation with PVC base
Cores stranded in layers
DIN colour code
Shield braid made from tinned wires
Transparent outer sheath made from special PVC-based mixture
Flame-retardant in accordance with VDE 0472, part 804, test type B (IEC 332.1)
Operating temperature with occasional flexing: -5°C to +70°C
Operating temperature with fixed installation: -40°C to +80°C
Applications
This CY multi-conductor cable is suitable for a variety of applications, such as;
RS 232
Process control
Communications, signal & control
Signal & broadcast
Accessories
Unitronic LiYCY cables should be used with accessories that mach its capabilities, and as such Lapp supplies a series of low-resistance screen cable glands.
839-5331 is an M16 Skintop EMC Cable Gland
839-5340 is an M20 Skintop EMC Cable Gland
839-5343 is an M25 Skintop EMC Cable Gland
839-5347 is an M32 Skintop EMC Cable Gland
839-5356 is an M40 Skintop EMC Cable Gland
839-5359 is an M50 Skintop EMC Cable Gland
The Unitronic LiYCY cable is flame retardant and suitable for use in dry or damp rooms.
Features and Benefits
Core insulation with PVC base
Cores stranded in layers
DIN colour code
Shield braid made from tinned wires
Transparent outer sheath made from special PVC-based mixture
Flame-retardant in accordance with VDE 0472, part 804, test type B (IEC 332.1)
Operating temperature with occasional flexing: -5°C to +70°C
Operating temperature with fixed installation: -40°C to +80°C
Applications
This CY multi-conductor cable is suitable for a variety of applications, such as;
RS 232
Process control
Communications, signal & control
Signal & broadcast
Accessories
Unitronic LiYCY cables should be used with accessories that mach its capabilities, and as such Lapp supplies a series of low-resistance screen cable glands.
839-5331 is an M16 Skintop EMC Cable Gland
839-5340 is an M20 Skintop EMC Cable Gland
839-5343 is an M25 Skintop EMC Cable Gland
839-5347 is an M32 Skintop EMC Cable Gland
839-5356 is an M40 Skintop EMC Cable Gland
839-5359 is an M50 Skintop EMC Cable Gland
Standards
VDE 482, VDE 0472, IEC 332.1 and DIN 47100 colour code
Lapp UNITRONIC LiYCY Series Data Cable, 50m Length, 250V Voltage Rating - 34325
This shielded Lapp data cable is a versatile multicore cable suitable for use in machinery, apparatus construction, and measurement, control, and regulation technology. With a flame-retardant sheath, tinned copper braid shield, and CPR certification, this cable ensures high performance and safety in various applications.
Features & Benefits
• Shielded PVC data cable with colour code according to DIN 47100
• Overall shield minimises electrical interference
• Flame-retardant according to IEC 60332-1-2
• Fine-wire/multi-wire core design for flexibility and durability
• Overall shield minimises electrical interference
• Flame-retardant according to IEC 60332-1-2
• Fine-wire/multi-wire core design for flexibility and durability
Applications
• Ideal for machinery and apparatus construction
• Suitable for use in measurement, control, and regulation technology
• Can be used in computer systems, office equipment, and scales
• Can be used for applications requiring shielded cables with small dimensions
• Suitable for use in measurement, control, and regulation technology
• Can be used in computer systems, office equipment, and scales
• Can be used for applications requiring shielded cables with small dimensions
Can it be used in computer systems?
Yes, this Lapp data cable is suitable for use in computer systems, offering reliable performance and data transmission.
Is it flame-retardant?
Yes, this cable is flame-retardant according to IEC 60332-1-2 standards, ensuring safety in various applications.
Will it minimise electrical interference?
Yes, the overall shield of this cable minimises electrical interference, making it ideal for sensitive equipment and systems.
What is the voltage rating?
The voltage rating of this cable is 250V, allowing for versatile use in different electrical setups.
Is it suitable for dry or damp rooms?
Yes, this cable is suitable for both dry and damp rooms, providing flexibility in installation options.
Attribute | Value |
---|---|
Cross Sectional Area | 0.14 mm² |
Number of Cores | 25 |
American Wire Gauge | 26 AWG |
Screened/Unscreened | Screened |
Length | 50m |
Shield Type | Tinned Copper Braid |
CPR Certification | Eca |
Sheath Colour | Grey |
Cable Type | LiYCY |
Outer Diameter | 8.5mm |
Outer Sheath Material | PVC |
Cable Shape | Multicore |
Series | UNITRONIC LiYCY |
Standards Met | CE |
Minimum Operating Temperature | -40°C |
Fire Behaviour | Flame Retardant |
Core Strands | 18/0.10 mm |
Maximum Operating Temperature | +80°C |
Voltage Rating | 250 V |
Shielded/Unshielded | Shielded |