Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac
- RS Stock No.:
- 811-1316
- Distrelec Article No.:
- 110-83-815
- Mfr. Part No.:
- FLK-3000 FC
- Manufacturer:
- Fluke
Subtotal (1 unit)*
€454.00
(exc. VAT)
€558.42
(inc. VAT)
- 10 left, ready to ship from another location
- Plus 10 left, shipping from 24 March 2026
- Plus 34 left, shipping from 27 March 2026
Units | Per unit |
|---|---|
| 1 + | €454.00 |
*price indicative
- RS Stock No.:
- 811-1316
- Distrelec Article No.:
- 110-83-815
- Mfr. Part No.:
- FLK-3000 FC
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Multimeter Type | Handheld | |
| Product Type | Multimeter | |
| Display Type | Digital | |
| Resistance Resolution | 100mΩ | |
| Model Number | 3000 FC | |
| Functions Measured | AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | |
| Maximum Resistance Measurement | 50mΩ | |
| Maximum DC Current Measurement | 400mA dc | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum AC Current Measurement | 400mA ac | |
| Maximum AC Voltage Measurement | 1kV ac | |
| True RMS | Yes | |
| AC Current Accuracy | ±1.5 % | |
| DC Current Accuracy | ±0.5 % | |
| AC Voltage Accuracy | ±1 % rdg | |
| DC Voltage Accuracy | ±0.09 % | |
| DC Voltage Resolution | 0.1 mV dc | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Current Resolution | 0.01mA dc | |
| AC Current Resolution | 0.01mA ac | |
| Maximum Frequency | 99.99kHz | |
| Resistance Measurement Accuracy | ±0.5 % rdg | |
| Minimum Operating Temperature | -10°C | |
| Maximum Operating Temperature | 50°C | |
| Battery Life | 250h | |
| Height | 47.5mm | |
| Length | 207mm | |
| Weight | 487.5g | |
| Standards/Approvals | No | |
| Series | 3000 FC | |
| Width | 93 mm | |
| Safety Category Level | CAT III, CAT IV | |
| Battery Type | AA | |
| Safety Category Voltage | 1000V | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Multimeter Type Handheld | ||
Product Type Multimeter | ||
Display Type Digital | ||
Resistance Resolution 100mΩ | ||
Model Number 3000 FC | ||
Functions Measured AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | ||
Maximum Resistance Measurement 50mΩ | ||
Maximum DC Current Measurement 400mA dc | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum AC Current Measurement 400mA ac | ||
Maximum AC Voltage Measurement 1kV ac | ||
True RMS Yes | ||
AC Current Accuracy ±1.5 % | ||
DC Current Accuracy ±0.5 % | ||
AC Voltage Accuracy ±1 % rdg | ||
DC Voltage Accuracy ±0.09 % | ||
DC Voltage Resolution 0.1 mV dc | ||
AC Voltage Resolution 0.1mV ac | ||
DC Current Resolution 0.01mA dc | ||
AC Current Resolution 0.01mA ac | ||
Maximum Frequency 99.99kHz | ||
Resistance Measurement Accuracy ±0.5 % rdg | ||
Minimum Operating Temperature -10°C | ||
Maximum Operating Temperature 50°C | ||
Battery Life 250h | ||
Height 47.5mm | ||
Length 207mm | ||
Weight 487.5g | ||
Standards/Approvals No | ||
Series 3000 FC | ||
Width 93 mm | ||
Safety Category Level CAT III, CAT IV | ||
Battery Type AA | ||
Safety Category Voltage 1000V | ||
RoHS Status: Exempt
- COO (Country of Origin):
- US
Fluke Multimeter, 1000V Maximum DC Voltage, True RMS Functionality - FLK-3000 FC
Features & Benefits
• True RMS measurement for accurate non‑sinusoidal waveforms
• 400 mA maximum current range for precision current checks
• Frequency measurement to 99.99 kHz for signal verification
• Resistance down to 50 mΩ for low‑ohm integrity testing
• AA battery operation with 250 h minimum battery life for prolonged field use
Applications
• Ideal for preventative maintenance log collection and trend analysis
• Used for motor drive frequency and signal validation in automation systems
• Can be used for HVAC temperature checks via K‑type probes
• Used with remote clamp modules for non‑intrusive current monitoring
How is logged data retrieved for analysis on a PC?
What wireless range can be expected through typical site obstacles?
How does the instrument handle non‑sine AC voltages for accuracy?
What logging capacity and granularity are available for extended monitoring?
Which environmental conditions affect measurement performance?
Note
Supplied with
Related links
- Fluke 3000 FC 3000 FC Handheld Digital Multimeter True RMS 400 mA Max, 1000 V ac Max
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1000 V ac Max
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1000 V Max
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1000 V ac Max
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1000 V Max
- RS PRO S2 Handheld Digital Multimeter True RMS 400 mA Max, 1000 V ac Max
- RS PRO S2 Handheld Digital Multimeter True RMS 400 mA Max, 1000 V Max
- Fluke Fluke 279 FC Handheld Digital Multimeter True RMS, 2.5 kA Max