Fluke 124 Series, 40 MHz Handheld Oscilloscope, 2 Channels - RSCAL
- RS Stock No.:
- 919-6778
- Mfr. Part No.:
- FLUKE-124B/UK
- Manufacturer:
- Fluke
Subtotal (1 unit)*
€3,048.50
(exc. VAT)
€3,749.66
(inc. VAT)
In Stock
- 6 unit(s) ready to ship
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | €3,048.50 |
*price indicative
- RS Stock No.:
- 919-6778
- Mfr. Part No.:
- FLUKE-124B/UK
- Manufacturer:
- Fluke
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Oscilloscope | |
| Bandwidth | 40MHz | |
| Number of Channels | 2 | |
| Oscilloscope Type | Handheld | |
| Oscilloscope Form | Digital | |
| Interface Type | CAN, RS232, RS422, RS485, USB | |
| Screen Size | 5.7 in | |
| Series | 124 | |
| Height | 55mm | |
| Standards/Approvals | IEC 61010-2-033, IEC 61010-4 | |
| Depth | 132mm | |
| Width | 55mm | |
| Battery Life | 7h | |
| Safety Category Level | CAT III, CAT IV | |
| Maximum Time Base | 500ns/div | |
| Minimum Time Base | 10ns | |
| Battery Type | Lithium-ion | |
| Plug Type | UK | |
| Display Type | TFT Colour | |
| Minimum Vertical Sensitivity | 5mV/div | |
| Calibrated | RSCAL | |
| Rise Time | 8.75ns | |
| Maximum Vertical Sensitivity | 200V/div | |
| Safety Category Voltage | 600V | |
| Power Source | Battery | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Oscilloscope | ||
Bandwidth 40MHz | ||
Number of Channels 2 | ||
Oscilloscope Type Handheld | ||
Oscilloscope Form Digital | ||
Interface Type CAN, RS232, RS422, RS485, USB | ||
Screen Size 5.7 in | ||
Series 124 | ||
Height 55mm | ||
Standards/Approvals IEC 61010-2-033, IEC 61010-4 | ||
Depth 132mm | ||
Width 55mm | ||
Battery Life 7h | ||
Safety Category Level CAT III, CAT IV | ||
Maximum Time Base 500ns/div | ||
Minimum Time Base 10ns | ||
Battery Type Lithium-ion | ||
Plug Type UK | ||
Display Type TFT Colour | ||
Minimum Vertical Sensitivity 5mV/div | ||
Calibrated RSCAL | ||
Rise Time 8.75ns | ||
Maximum Vertical Sensitivity 200V/div | ||
Safety Category Voltage 600V | ||
Power Source Battery | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
Fluke 120B Series Oscilloscope, 40 MHz Bandwidth, 2 Analogue Channels - FLUKE-124B/UK
This digital oscilloscope is designed for versatility in various electrical and electronic applications. With a bandwidth of 40MHz and a Compact handheld design, it measures 259 x 132 x 55 mm and weighs only 1.4kg. The device features a 5.7-inch TFT colour display, providing clear and precise waveforms in any working environment. This battery-powered oscilloscope supports up to two analogue channels, perfect for engineers requiring portable instrumentation.
Features & Benefits
• Compact design facilitates easy portability and quick setup
• 40MHz bandwidth allows for detailed signal analysis
• Dual analogue channels enable simultaneous monitoring of signals
• Multiple communication interfaces enhance connectivity options
• Long battery life of 7 hours supports extended field use
• 40MHz bandwidth allows for detailed signal analysis
• Dual analogue channels enable simultaneous monitoring of signals
• Multiple communication interfaces enhance connectivity options
• Long battery life of 7 hours supports extended field use
Applications
• Used for troubleshooting in automation equipment
• Utilised in maintenance of electrical circuits
• Ideal for diagnostics in electrical and mechanical systems
• Effective for signal analysis in electronic development
• Utilised in maintenance of electrical circuits
• Ideal for diagnostics in electrical and mechanical systems
• Effective for signal analysis in electronic development
How does the sampling rate affect the measurement accuracy?
The oscilloscope offers a sampling rate of 400 Ksps, ensuring high-resolution signal representation and accurate measurements for various applications, Crucial for capturing fast-changing waveforms.
What types of measurements can it handle safely?
It is rated for safety categories CAT III 750V and CAT IV 600V, enabling safe measurements in high-voltage environments, making it suitable for fieldwork and maintenance tasks.
How do the Interface options benefit users?
With CAN, RS232, RS422, RS485, and USB interfaces, the device allows seamless connectivity to other equipment and systems, enabling data transfer and remote monitoring during diagnostics.
What is the significance of the input impedance?
Having an input impedance of 1 MΩ minimises the loading effect on the circuit under test, ensuring accurate signal acquisition without adversely affecting circuit performance.
Can its display be easily read in different lighting conditions?
The TFT colour display provides excellent visibility even in bright environments, allowing for effective utilisation in diverse working conditions.
Note
The 40 MHz Fluke 124B includes scope cursor measurements.
Standards
IEC 61010-1: Pollution Degree 2, IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Supplied with
Li-Ion battery pack, charger/power adapter, 2 shielded test leads with ground leads, black test lead, red and blue hook clips, banana to BNC adapter, 10:1 voltage probe