Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator, RSCAL
- RS Stock No.:
- 192-5840
- Mfr. Part No.:
- FLUKE-718EX 300G
- Manufacturer:
- Fluke
Subtotal (1 unit)*
€5,656.00
(exc. VAT)
€6,956.88
(inc. VAT)
Limited stock
- 2 left, ready to ship from another location
- Plus 3 left, shipping from 07 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | €5,656.00 |
*price indicative
- RS Stock No.:
- 192-5840
- Mfr. Part No.:
- FLUKE-718EX 300G
- Manufacturer:
- Fluke
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Pressure Calibrator | |
| Maximum Pressure Measurement | 20bar | |
| Battery Type | Alkaline | |
| Accuracy | ±0.05 % | |
| Minimum Pressure Measurement | -830mbar | |
| Resolution | 0.0001 bar | |
| Pressure Port Type | Vacuum | |
| Model Number | 718 EX | |
| Data Logging | No | |
| Intrinsically Safe | Yes | |
| Current Loop Measurement | Yes | |
| Display Type | LCD | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 992g | |
| Maximum Operating Temperature | 55°C | |
| Battery Life | 20h | |
| Standards/Approvals | No | |
| Width | 94mm | |
| Length | 216mm | |
| Height | 66mm | |
| Hazardous Area Certification | ATEX | |
| Calibrated | RSCAL | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Pressure Calibrator | ||
Maximum Pressure Measurement 20bar | ||
Battery Type Alkaline | ||
Accuracy ±0.05 % | ||
Minimum Pressure Measurement -830mbar | ||
Resolution 0.0001 bar | ||
Pressure Port Type Vacuum | ||
Model Number 718 EX | ||
Data Logging No | ||
Intrinsically Safe Yes | ||
Current Loop Measurement Yes | ||
Display Type LCD | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 992g | ||
Maximum Operating Temperature 55°C | ||
Battery Life 20h | ||
Standards/Approvals No | ||
Width 94mm | ||
Length 216mm | ||
Height 66mm | ||
Hazardous Area Certification ATEX | ||
Calibrated RSCAL | ||
Fluke Pressure Calibrator, 20 Bar Maximum Pressure Measurement, ±0.05 % Accuracy - FLUKE-718EX 300G
This handheld pressure calibrator is an intrinsically safe, battery-powered instrument for field pressure and current loop verification in hazardous locations. It combines a self-contained pressure/vacuum hand pump with measurement functions to support technicians working on control valves, transmitters and switch testing in explosive atmospheres.
Features & Benefits
• Intrinsically safe ATEX approval enables use in classified areas
• Pressure range from -830 mbar to 20 bar supports wide measurement needs
• Pressure measurement accuracy ±0.05% of full span for precise calibration
• Resolution 0.0001 bar for fine incremental pressure readings
• 4–20 mA measurement with 0.02% accuracy and 0.001 mA resolution for loop checks
• Battery operation delivers up to 20 h runtime for extended field shifts
• Pressure range from -830 mbar to 20 bar supports wide measurement needs
• Pressure measurement accuracy ±0.05% of full span for precise calibration
• Resolution 0.0001 bar for fine incremental pressure readings
• 4–20 mA measurement with 0.02% accuracy and 0.001 mA resolution for loop checks
• Battery operation delivers up to 20 h runtime for extended field shifts
**Applications**
• Suitable for calibrating pressure transmitters in hazardous zones
• Ideal for pressure switch testing on-site using the integrated pump
• Used for commissioning pneumatic control systems in process plants
• Can be used for routine verification of 4–20 mA loops on instrumentation panels
• Ideal for pressure switch testing on-site using the integrated pump
• Used for commissioning pneumatic control systems in process plants
• Can be used for routine verification of 4–20 mA loops on instrumentation panels
What power source does it use for remote work?
It is powered by a single 9V alkaline battery, with runtime varying by function from 4 h up to 20 h.
Which media are compatible with the internal sensor?
The internal sensor is specified for dry Air or non-corrosive gases
pressure modules use 316 stainless steel or Hastelloy C276 where indicated.
How is pressure input connected for external modules?
External pressure modules attach via a LEMO connector while the pressure input uses a 1/8 in NPT fitting.
What environmental limits affect safe operation?
Operating temperature is -10 °C to +55 °C and relative humidity limits vary by temperature without condensation.
Standards
ATEX II 1G EEx ia IIC T4 compliant, CSA I.S. Class I, Div. 1 Groups A-D, T4, EN 61326 2002-2, Class C
Supplied with
Protective red holster, TL75 test leads, set of test clips (red and black).
Related links
- Fluke 718 EX -830 mbar to 20 bar Pressure Calibrator
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke -850mbar to 2bar 718 Pressure Calibrator
- Fluke 718 -12psi to 100psi Pressure Calibrator - With RS Calibration
- Fluke 718 -850 mbar to 2 bar Pressure Calibrator
- Fluke 718 -850 mbar to 6.895 bar Pressure Calibrator
- Fluke 717 -850 mbar to 20.68 bar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 20 bar Pressure Calibrator
