Allen Bradley 1492-RCDA RCD, 40A, 3+N Pole, 100mA, Type A
- RS Stock No.:
- 136-8606
- Mfr. Part No.:
- 1492-RCDA4B40S
- Manufacturer:
- Allen Bradley
Subtotal (1 unit)*
€258.37
(exc. VAT)
€317.80
(inc. VAT)
Temporarily out of stock
- Shipping from 22 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | €258.37 |
*price indicative
- RS Stock No.:
- 136-8606
- Mfr. Part No.:
- 1492-RCDA4B40S
- Manufacturer:
- Allen Bradley
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Allen Bradley | |
| Circuit Breaker Type | RCD | |
| Current Rating | 40A | |
| Number of Poles | 3+N | |
| Trip Sensitivity | 100mA | |
| Tripping Characteristics | Type A | |
| Series | 1492-RCDA | |
| Standards Met | IEC/EN 61008, UL 1053 | |
| Overall Length | 70mm | |
| Break Time | Time Delay | |
| Breaking Capacity at Maximum Voltage Rating | 1 (Residual) kA, 10 (Short-Circuit) kA | |
| Rated AC Voltage | 230 V, 400V | |
| Mounting Style | DIN Rail Mount | |
| Overall Depth | 75mm | |
| Terminal Contact Type | Screw | |
| Reset Actuator Type | Toggle Switch | |
| Overall Dimensions | 70 x 88 x 75mm | |
| Overall Width | 88mm | |
| Select all | ||
|---|---|---|
Brand Allen Bradley | ||
Circuit Breaker Type RCD | ||
Current Rating 40A | ||
Number of Poles 3+N | ||
Trip Sensitivity 100mA | ||
Tripping Characteristics Type A | ||
Series 1492-RCDA | ||
Standards Met IEC/EN 61008, UL 1053 | ||
Overall Length 70mm | ||
Break Time Time Delay | ||
Breaking Capacity at Maximum Voltage Rating 1 (Residual) kA, 10 (Short-Circuit) kA | ||
Rated AC Voltage 230 V, 400V | ||
Mounting Style DIN Rail Mount | ||
Overall Depth 75mm | ||
Terminal Contact Type Screw | ||
Reset Actuator Type Toggle Switch | ||
Overall Dimensions 70 x 88 x 75mm | ||
Overall Width 88mm | ||
- COO (Country of Origin):
- IT
Allen Bradley RCD, 1kA Breaking Capacity, Screw Terminals - 1492-RCDA4B40S
This Allen Bradley RCD from Rockwell Automation detects earth leakages in your electrical circuit and cuts the power supply should conditions become dangerous. Thanks to a trip sensitivity of 100mA, it's suitable for protecting people against electric shocks, as well as safeguarding equipment against short circuits and current overload. A low power loss of 3.2W means you can rely on the device to be energy-efficient. A toggle switch allows you to manually reset the unit after a fault has been detected. Its screw terminals hold wires securely, so there's less need for maintenance and wire tightening.
• Compact dimensions of 70 (L) x 88 (W) x 75mm (D) to maximise circuit-board packing efficiency
• Broad operating temperature range between -25°C and +55°C, making it compatible with harsh environments
• IP4X-rated housing is protected against water spray and objects larger than 1mm
• Mechanical endurance of up to 20,000 operations, for an extended service life
Standards and Certifications
• CE
• CCC
• CSA
• UL
• RoHS
• GB
How do I know if this RCD is on?
This device has an indicator window that let's you conveniently see when it's on or off.
1492 Series
Allen Bradley general purpose RCDs from the 1492 series. The RCDs have a Type A tripping characteristic and an instantaneous break time. 2 or 4 pole versions available. All the RCDs incorporate screw terminals and can be DIN Rail mounted.
Features & Benefits
2 or 4 pole versions
DIN Rail mount
Screw Terminals
Allen Bradley RCBs
Related links
- Allen Bradley 1492-RCDA RCD 3+N Pole Type A
- Allen Bradley 1492-RCDA RCD 3+N Pole Type A
- Allen Bradley 1492-RCDA RCD 3+N Pole Type A
- Allen Bradley 1492-RCDA RCD 3+N Pole Type A
- Allen Bradley 1492-RCDA RCD 3+N Pole Type A
- Allen Bradley 1492-RCDA RCD 3+N Pole Type A
- Allen Bradley 1492-RCDA RCD 2 Pole Type A